Aqua OC-105B Скачать руководство пользователя страница 8

SG-B SERIES                                                                                                                                    STEAM GENERATOR 

  8                                                                                                                                                          E005-28-10-12   

 

   

 
The following table should be referred to for guidance only. Please note that the size of heater required to 
heat  a  particular  size  of  steam  room  will  vary  according  to  a  number  of  factors  including  the  type  of 
material used for construction, the height of the steam room and the ambient temperature. 
 
For lightweight materials such as plastics and laminates 1 KW will heat up to 1 cubic meter of air for dense 
materials such as stones and ceramics which will conduct the heat away more rapidly allow for up to 2KW 
per cubic meter of air. Hot air rises so restricting the height to around 2 meters will ensure the user is sitting 
in the steam for higher ceilings you may need to increase the power requirement. 
 
The  following  table  is  given  as  a  guide,  ambient  air  temperatures  and  frequency  of  use  (number  of  door 
openings) can also affect the power requirements. 

 

Installation   
The steam generator should be installed in dry well ventilated place in close proximity to the steam room. It 
can be placed on the floor or hung on wall. In order for installing and maintenance, please refer the Fig-7 to 
prepare enough space . 
To hang the generator on a wall drill 3 holes 8mm in diameter in accordance with the table below and use 
the  wall  plugs  and  screws  provided.  Fix  the  top  2  screws  in  place  first  then  hang  the  generator  by  the  2 
keyhole shaped holes in the back plate. Then with the front cover removed fix the 3rd screw to secure the 
unit in place. 

OC-B

(

 

 

     

   

 

)

c ontroller

can be either in or

out of s team room

OC-B s team generator

insulation

closet

steam noz z le

under was hing basin

bas ement

 

Fig-6 

Min500

M

in

30

0

Min400

Min500

Unit

(

mm

)

 

Содержание OC-105B

Страница 1: ......

Страница 2: ...solator This equipment must be installed by a competent person Disconnect the power supply before exposing electrical connections Confirm the right voltage to your steam generator 1 or 3 phase SAFETY...

Страница 3: ...7 530 230 460 SG 180B O C 180B 18 0 230 400 1 3 78 0 26 1 530 230 460 Remarks if greater power is required one OC B controller may be used to control two or more steam generators e g if you need a 30K...

Страница 4: ...the time widow displays Long the generator will operate continuously until it is switched off OC S 30 60 60 Steam on demand switch press once it will work 30 minutes press again it stop works special...

Страница 5: ...12MPa 10 Overheat switch Boil dry protector operates at 110 11 Main circuit board Control center 12 Accessorial circuit board Connect and control the heat element 13 terminal Connection for power supp...

Страница 6: ...r LED for over heat red means the steam generator was cut off as the heat element is too hot lack of water the heat elements may worked in air 16 Fan LED Indicator LED for Fan the lamp of steam room i...

Страница 7: ...re that the track of the pipe does not create a trap into which condensate would gather and cause a blockage I e the pipe must not go down and then up There must be no valve or other blockage in the s...

Страница 8: ...the power requirement The following table is given as a guide ambient air temperatures and frequency of use number of door openings can also affect the power requirements Installation The steam genera...

Страница 9: ...e steam nozzle should be installed in the place which is far from the seat 300 overheat switch Fig 8 d Connect the drain outlet to a suitable drain via a copper pipe with the appropriate fittings e Ma...

Страница 10: ...in place and then connect to the wire from the controller temperature sensor 4 scr ew Fig 10 Installation for power supply and control cable Confirm the correct voltage of power supply and wires Remov...

Страница 11: ...in On RED D5 Liquid Inlet On RED D4 Reserve1ON RED D3 Light On RED D2 D1 RED Fan On LED COLOR KEY Fig 11 Tank H2 H1 V DC5V Switch C F 4 4 2 7 12Kw Steam Generator Circuit Diagram 2 JP1 OC S Controller...

Страница 12: ...ve the knock out for the control cable entry and use a rubber grommet to protect the cable connect the cable to the relevant port on circuit board Ensure the power supply wire and control cable remain...

Страница 13: ...display counts down to show the remaining time when it reaches 0 the steam generator will stop heating 8 Once the steam generator has operated for 10 minutes or more when it is turned off manually or...

Страница 14: ...he OFF mode i e the boiler has finished steaming the water has drained and flushed the drain LED is off Before auto descaling can commence a supply of dilute citric acid liquid must be connected from...

Страница 15: ...anel 5 control cable or port 4 if use circuit board the steam generator can work normally check the control cable port and controller Something wrong with 1 indicator LED for water level is red check...

Страница 16: ...rcial operators we recommend the use of a water softener All users commercial and domestic must ensure a regular maintenance routine for descaling the generator The frequency of this will vary accordi...

Страница 17: ...ators are guaranteed for 12 months from the date of purchase This guarantee excludes consumable items such as the electrical elements and failures resulting from misuse or abuse such as a failure to d...

Отзывы: