Chapter three: installation   

  Isolate the power supply before installation   

  Confirm the model you have selected is suitable for your steam room, please refer to

 

chart 5 

 

  Mount the steam inlet nozzle approximately 300mm up from the floor and it should be at least 200mm 

from person's body. 

  If  the  steam  generator  is  installed  in  an  inaccessible  place  ensure  that  both  the  electrical  power  and 

water supply can be isolated in an emergency. 

  The  minimum  water  inlet  pressure  is  0.025MPa  and  the  maximum  is  0.8MPa,  advise  the  water 

pressure not exceed 0.5MPa 

  The steam pipe from steam generator to steam room should be kept to a minimum, pipes longer than

 5 

meters should be insulated to prevent heat loss. Steam pipes will be hot during use and must be protected 
against accidental contact. 

  Keep  the  number  of  right  angle  bends  to  a  minimum  and  ensure  that  the  track  of  the  pipe  does  not 

create a trap into which condensate would gather and cause a blockage. I.e. the pipe must not go down and 
then up. 

  There must be no valve or other blockage in the steam pipe 

  The steam pipe should be metal of other material which can endure 150

°

C temperature, copper pipe 

is recommended. 

  It is not recommended to install the Steam generator outdoors or where it might be affected by frost. 

Allow for a minimum space of 0.5 cubic meters to install the generator. 

  Steam  generator  should  be  level  side  to  side  and  front  to  back  and  should  be  installed  so  that  the 

arrows on the case point up. 

  Do not install the steam generator in close proximity to hazardous substances. 

Chart 5

 

Model 

Po
wer 

Steam room volume 

(m

3

Model 

Power 

Steam room volume 

(m

3

SG-30B     

3.0

KW 

1.5-3 

SG -100B     

10.0K

6 - 11 

SG -40B     

4.0

KW 

1.8 - 4 

SG -105B     

10.5K

7 - 11 

SG -45B     

4.5

KW 

1.8

 5 

SG -110B     

11.0K

7 - 12 

SG -50B     

5.0

KW 

2.5 

 5 

SG -120B     

12.0K

8-12   

SG -60B     

6.0

KW 

4 -6 

SG -135B     

13.5K

11-1 6 

SG -70B     

7.0

KW 

5 -7 

SG -150B     

15.0K

11-1 6 

SG 80B     

8.0

KW 

5-9 

SG -180B     

18.0K

13-19

 

 

SG -90B     

9.0

KW 

6 - 10   

 

 

Содержание OC-105B

Страница 1: ......

Страница 2: ...solator This equipment must be installed by a competent person Disconnect the power supply before exposing electrical connections Confirm the right voltage to your steam generator 1 or 3 phase SAFETY...

Страница 3: ...7 530 230 460 SG 180B O C 180B 18 0 230 400 1 3 78 0 26 1 530 230 460 Remarks if greater power is required one OC B controller may be used to control two or more steam generators e g if you need a 30K...

Страница 4: ...the time widow displays Long the generator will operate continuously until it is switched off OC S 30 60 60 Steam on demand switch press once it will work 30 minutes press again it stop works special...

Страница 5: ...12MPa 10 Overheat switch Boil dry protector operates at 110 11 Main circuit board Control center 12 Accessorial circuit board Connect and control the heat element 13 terminal Connection for power supp...

Страница 6: ...r LED for over heat red means the steam generator was cut off as the heat element is too hot lack of water the heat elements may worked in air 16 Fan LED Indicator LED for Fan the lamp of steam room i...

Страница 7: ...re that the track of the pipe does not create a trap into which condensate would gather and cause a blockage I e the pipe must not go down and then up There must be no valve or other blockage in the s...

Страница 8: ...the power requirement The following table is given as a guide ambient air temperatures and frequency of use number of door openings can also affect the power requirements Installation The steam genera...

Страница 9: ...e steam nozzle should be installed in the place which is far from the seat 300 overheat switch Fig 8 d Connect the drain outlet to a suitable drain via a copper pipe with the appropriate fittings e Ma...

Страница 10: ...in place and then connect to the wire from the controller temperature sensor 4 scr ew Fig 10 Installation for power supply and control cable Confirm the correct voltage of power supply and wires Remov...

Страница 11: ...in On RED D5 Liquid Inlet On RED D4 Reserve1ON RED D3 Light On RED D2 D1 RED Fan On LED COLOR KEY Fig 11 Tank H2 H1 V DC5V Switch C F 4 4 2 7 12Kw Steam Generator Circuit Diagram 2 JP1 OC S Controller...

Страница 12: ...ve the knock out for the control cable entry and use a rubber grommet to protect the cable connect the cable to the relevant port on circuit board Ensure the power supply wire and control cable remain...

Страница 13: ...display counts down to show the remaining time when it reaches 0 the steam generator will stop heating 8 Once the steam generator has operated for 10 minutes or more when it is turned off manually or...

Страница 14: ...he OFF mode i e the boiler has finished steaming the water has drained and flushed the drain LED is off Before auto descaling can commence a supply of dilute citric acid liquid must be connected from...

Страница 15: ...anel 5 control cable or port 4 if use circuit board the steam generator can work normally check the control cable port and controller Something wrong with 1 indicator LED for water level is red check...

Страница 16: ...rcial operators we recommend the use of a water softener All users commercial and domestic must ensure a regular maintenance routine for descaling the generator The frequency of this will vary accordi...

Страница 17: ...ators are guaranteed for 12 months from the date of purchase This guarantee excludes consumable items such as the electrical elements and failures resulting from misuse or abuse such as a failure to d...

Отзывы: