20
L0200390
EQUO SOFT
Rev.2.2
10/11/2015
PROGRAMMING
To unlock the valve you need to keep pushing on the arrows
and
for 5 seconds (spy
off).
With the unlock valve, press the button
to access programming.
The programming menu scroll through arrows
and
.
To enter the editing of the individual parameters is necessary to press the button
.
Function
Display
Range
Note
Mode
A-01
Mode
A-02
Mode
A-03
Mode
A-04
Current time
00,00 -
23,59
Indicate the actual time
to be set
Way of
regeneration
A-01
A-02
A-03
A-04
A=1 Regeneration vol. delayed.
A=2 Regeneration vol. immediate.
A=3 Regeneration vol. delayed
with automatic calculation of the
yield cyclic
A=4 Rigenerazione vol. immediate
with automatic calculation of the
yield cyclic
to be set
Unit of
measure
HU 01
HU 02
HU 03
HU 01= m3
HU 02= gal
HU 03= l
deafult HU 01
Unit of
measure
00,00 -
23,59
If you choose the delayed
regeneration set at what time must
start the regeneration.
to set default 02:00
Interval
backwashing
0- 20
For ex. F-03 indicates that the
backwash is carried out once every
3 regenerations. F-00 indicates
that the backwash is performed at
each regeneration.
to set default F-00
Softener
resins
5 - 500
Indicate the volume of the softener
resins
not required -
not displayed
to set the
volume of the
softener resins
Water
hardness
(mmol/L)
Yd 0,1 -
9,9
Indicate that the hardness removed
from the water softener in °F
divided by 10
• ex
. Hardness input 40 °F -
Hardness Output 10 °F = 30 °F
removed, set 3.0
• ex
. Hardness input 50 °F -
Hardness Output 15 °F = 35 °F
removed, set 3.5
not required -
not displayed
to be set