STANDARD CONSOLE
ALARMS
Control console for
eco•wash
system
ENGLISH
ADSP7000604
rev. 1.3
17/09/2015
20/62
3.12 O
THER MESSAGES
Message
Meaning
Priming
in progress
The priming has been performed using
the button on the pump.
PC conn. hh:mm
<<<<< >>>>>
The system is not active as connected
to computer
4.0 ALARMS
4.1
A
LARM MESSAGES
During functioning, the console can display the following alarm messages:
Message
Meaning
Solutions
Alarm deactivation
Alarm P##!
(with levels
module)
The product tank of P##
pump is empty.
Replace tank or fill it.
Yes, keep the
Enter
key pressed.
Low level alarm!
The tank of one of the
chemical products is
empty.
Replace tank or fill it.
Yes, keep the
Enter
key pressed.
Autostart
alarm!
The autostart mode has
selected a program greater
than 20.
Check autostart programming.
No, eliminate alarm
cause.
No water!
Water is not passing
through the flushing kit
Check correct electric connection
of the solenoid valve and if water
is present.
No, eliminate alarm
cause.
Pump
alarm ## !
Pump ## is not functioning
correctly.
Check tube, motor and roller
carrier of the pump.
No, eliminate alarm
cause.
Maintenance
alarm!
The maintenance alarm
has triggered.
Call after-sales assistance.
Yes, keep the
Enter
key pressed.
Calibration alarm!
The calibration alarm has
triggered.
Call after-sales assistance.
Yes, keep the
Enter
key pressed.
Alarm
module x!
Communication problems
with module x.
Check connection cable and
connection of the RJ11 connector
on the circuit.
No, eliminate alarm
cause.
LOADING ERROR
System initialisation
problems.
Switch the system off and on.
Not possible.
Program ERROR!
Problems on a program
start.
Check autostart programming.
Yes, keep the
Enter
key pressed.
To disable the buzzer (buzzer) an alarm, press the Enter key for three seconds and if it is off it is also
disabled.