STANDARD CONSOLE
FUNCTIONING
Control console for
eco•wash
system
ENGLISH
ADSP7000604
rev. 1.3
17/09/2015
19/62
3.11
Summary table
Method
Operation
Keys
What is shown on
display
stand-by
Washing programs
selection
With keys
it is possible
to select the washing
program
The program name and
number if it has been
programmed
stand-by
Execution of the washing
program
Using key
►
it is possible
to start the selected washing
program
The program name and
number if it has been
programmed and the
washing time.
stand-by
Pumps priming
Keep the
Enter
key pressed
for about 3 seconds
Pump 1 priming
stand-by
Diagnostic 1
Press key
F
Check the functioning
pumps and the active
input signals
stand-by
Diagnostic 2
Simultaneously press the
ENTER
and
F
keys for about
3 seconds
Check of the
transmission between
the various modules
execution of the
washing program
Place program in pause
Keep the
►
key pressed
for about 3 seconds
execution of the
washing program
Diagnostic 1
Press key
F
Check functioning
pumps and the active
input signals
pause
Return to stand-by mode
(exit from washing
program)
Briefly press the
ENTER
key
and then confirm, again with
the
ENTER
key
The program name and
number if it has been
programmed and the
washing time.
pause
Return to execution mode
of the washing program
Briefly press key
►
The program name and
number if it has been
programmed and the
washing time.
priming
Pump selection
Using keys
it is possible
to select the wanted pump
The pump number from
1 to 10 cyclically.
priming
Start of the wanted pump
Using the
►
key it is
possible to start the selected
pump for one minute
The number of the
selected pump and the
symbol indicating that
the pump is functioning
priming
Pump stop
Using the
►
key it is
possible to stop the selected
pump
The number of the
selected pump.
priming
Return in stand-by mode
Keep the
ENTER
key
pressed for about 3 seconds
Wait
diagnostic 1
Exit diagnostic 1 mode
Press the
F
key or wait 30
seconds
Return previous mode
diagnostic 2
Check and verification of
the various functionalities
Using the
F
key it is possible
to scroll the various
functionalities to verify
Signals module
Pumps module
Central module, etc.
diagnostic 2
Return in stand-by mode
Press the
ENTER
key or wait
30 seconds
Wait