STANDARD CONSOLE
FUNCTIONING
Control console for
eco•wash
system
ENGLISH
ADSP7000604
rev. 1.3
17/09/2015
15/62
3.0 FUNCTIONING
The control console depending on the mode in which it was programmed the
eco•wash
system during the booting
(initialization phase), shows:
Prg:--
: Standard (program) mode
PrgAT:NA
: Timed autostart mode
PrgAC:NA
: Combination autostart mode
Pg:Relay
: Relay mode
The initialization phase occurs each time the system is switched on and at the connection to the
computer.
3.1
D
ISPLAY AND KEYS
The fully digital system interface is made of an alphanumerical display (2 rows for 16 characters) and a membrane
keyboard (five keys).
: Keys used for selecting the washing program (operator/installer)
/►
: Keys used for start-up and pausing of a washing program (operator/installer).
Enter
: Key used to confirm and start the manual priming mode (installer)
F
: Key used to scroll the menu entries and to select the diagnostic mode (installer)
3.2
Standard (program) mode
3.2.1 In stand-by
In this phase the display shows:
hh:mm hour and minutes
When the console is in stand-by mode, it is possible to perform the following operations:
Selection of the washing program by pressing keys
> the second row of the display shows the
program name.
Execution of the washing program > briefly press key
/►
The system requests selecting the load made on the washing machine; with keys
it is possible to
select the load among 25/50/75 and 100%. To exit and return in stand-by, press the
F
key, whereas, to
definitively start the program, press the
Enter
key.
Priming of the pumps > keep the
Enter
key pressed for about 3 seconds
Diagnostic 1 mode > press the
F
key
Diagnostic 2 mode > keep keys
F
and
Enter
simultaneously pressed for about 3 seconds
Display adjustments > keep keys
/►
and
Enter
simultaneously pressed for about 3 seconds
3.2.2 In execution
When a program is in execution, the display shows the following:
The information on the display is:
The number of program in execution.
The status of the program that can be: ► in execution or
in pause.
The duration of the washing program, expressed in minutes (the first minute in seconds).
The name of the program in execution and the load appear, in alternate, on the second row.
If the names of the programs were not programmed by default, the console shows
Program #.
When the console is executing a washing program, it is possible to perform the following operations:
Place the washing program in pause > keep key
/►
pressed for about 3 seconds
Diagnostic 1 mode > press the
F
key
Diagnostic 2 mode > keep keys
F
and
Enter
simultaneously pressed for about 3 seconds
Display adjustments > keep keys
/►
and
Enter
simultaneously pressed for about 3 seconds
Prg:--
hh:mm
Wait
Prg:##
[Status] [Duration]
m
[program name]