background image

AHS - 99/01-05-2015

Содержание AQUATEX AHS 04/06

Страница 1: ...S AQUAPUMP INDUSTRIES MANUFACTURED BY MANUFACTURED BY TUDIYALUR POST COIMBATORE 641 034 INDIA E mail marketing aquagroup in Website www aquagroup in TUDIYALUR POST COIMBATORE 641 034 INDIA E mail marketing aquagroup in Website www aquagroup in FOR MODELS TEXMO AHS 02 03 AHS 02 06 AHS 04 04 FOR MODELS TEXMO AHS 02 03 AHS 02 06 AHS 04 04 AQUATEX AHS 04 06 AHS 04 08 AQUATEX AHS 04 06 AHS 04 08 ...

Страница 2: ...ble operation When you order spares in future please inform the name plate detail viz serial number pump type and other datas Spare parts list of the pumpset is given in this manual for your reference This pumpset should be installed by technically qualified personnel in compliance in order to avoid unsatisfactory performance and equipment failure Thank you ...

Страница 3: ...essure losses and should either be eliminated or used sparingly If flexible hoses are used note that it should be non collapsible 3 A larger diameter suction pipe may be used in case the suction distance is more 4 Ensure minimum number of bends and airtight joints PRIMING 1 A good quality foot valve should be used to avoid priming problems since the pumpset is not self priming 2 It is necessary to...

Страница 4: ...hs 4 The pumpset should be properly earthed to avoid electric shock DIRECTION OF ROTATION The pumpset should run clockwise when viewed from cooling fan side MAINTENANCE 1 Do not wrap the motor with airtight materials such as polythene sheet Condensation will form in tightly wrapped motor and damage the pumpset 2 Bearing needs no lubrication for 3 years under normal conditions When re greasing only...

Страница 5: ...should be given at cooling cover side Contact authorized service agent dealer for service repair Don t use for lifting impure water or other liquids Don t use smaller pipes or nipples than recommended Don t use jute ropes or any other sealing materials Don t use flexible hoses that will affect performance Avoid too many bend that will affect performance Don t place the pumpset in open space withou...

Страница 6: ...EXPLODED VIEW WITH PART NUMBERS ...

Страница 7: ...L SEAL ASSY SEAL LOCKING COLLAR STATOR FRAME TERMINAL BOX COVER TERMINAL BOARD TERMINAL BOX COVER SCREW TERMINAL BOARD SCREW DEL BRAC FRAME HEX BOLT 1 4 8 1 STAGE 1 Upto 4 Stages STAGE 2 6 Stages above 1 Only for 6 Stages above 1 Stage 2 2 STAGE x 2 2 Upto 4Stages STAGE x 2 4 6Stages above 1 Stage 2 1 1 1 1 1 1 1 1 1 2 1 4 CAST IRON MS ZINC COATED MS ZINC COATED CAST IRON SS AISI 304 SS AISI 304 L...

Страница 8: ...VE 4 1 for 0 5 1 HP 2 for 1 5 2 HP 2 1 1 1 1 4 1 1 1 Only for 6 Stages above MS ZINC COATED MS ZINC COATED CAST IRON SS MS PLASTIC MS ZINC COATED SS SS AISI 410 SS AISI 304 BEARING AND CAPACITOR CHART TYPE HP BEARING MOTOR RUN CAPACITOR 440 VOLTS QUANTITY FRONT BACK TEXMO AHS 02 03 AHS 02 06 AHS 04 04 0 5 1 0 1 0 6304 ZZ 6304 ZZ 6304 ZZ 6203 ZZ 6203 ZZ 6203 ZZ 15 MFD 25 MFD 25 MFD 1 1 1 AQUATEX AH...

Страница 9: ...XMO 1 AHS 02 03 1 x 1 BSP 380 0 200 0 190 0 0 5 2 AHS 02 06 500 0 200 0 190 0 1 0 1 1 4 x 1 1 4 BSP 3 AHS 04 04 450 0 200 0 190 0 1 0 AQUATEX 4 AHS 04 06 1 1 4 x 1 1 4 BSP 530 0 230 0 196 0 1 5 5 AHS 04 08 610 0 250 0 196 0 2 0 W L H OVERALL DIMENSION CHART ...

Страница 10: ...tomer 4 The warranty extended therein is in lieu of all implied conditions and warranties under the law and is confined to the repair or replacement of defective parts and does not cover any consequential or resulting liability damage or loss arising from such defects Further more the warranty in no case shall extend to the payment or any monetary consideration whatsoever of the replacement or ret...

Страница 11: ...AHS 99 01 05 2015 ...

Отзывы: