![Aqua-world PASRW010 Скачать руководство пользователя страница 22](http://html.mh-extra.com/html/aqua-world/pasrw010/pasrw010_instruction-manual_2959363022.webp)
6.APPENDIX
1.Connection of PCB illustration
20
Connections explanation
No.
Symbol
Meaning
1
OUT1
Compressor of system1 220-230VAC
2
OUT2
Water pump 220-230VAC
3
OUT3
4way valve 220-230VAC
4
OUT4
Fan motor 220-230VAC
5
OUT5
No use
6
AC-N
Neutral wire
7
NET GND 12V
Wire controller
8
DI01 GND
On/Off Switch(input)
9
DI02 GND
Flow switch (input)
10
DI03 GND
Low pressure switch
11
DI04 GND
High pressure switch
12
DI05 GND
No use
13
DI06 GND
No use
14
AI01 GND
Suction temp.(input)
15
AI02 GND
Water in temp.(input)
16
AI03 GND
Water out temp.(input)
17
AI04 GND
Coil Temp. ( input)
18
AI05 GND
Ambient temp.(input)
19
AI06 GND
Ajustable fan speed/Exhaust temperature
20
CN1
Primary transformer
21
CN2
Secondary transformer
22
CN6
No use
23
CN19
No use
24
5V CN16 GND
No use
OUT1
OUT2
CN19
3
4
OUT3
OUT4
OUT5
P
P
C
C
1
1
0
0
0
0
1
1
AC-N
CN1 CN2
CN
6
CN4
GND
AI06
GND
AI05
GND
AI04
GND
AI03
GND
AI02
GND
AI01
+5V
CN16
GND
CN3
3
4
V
E
T
G
I
G
I
G
I
G
I
G
I
G
I
G
Содержание PASRW010