![Aqua-world PASRW010 Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/aqua-world/pasrw010/pasrw010_instruction-manual_2959363012.webp)
10
3.INSTALLATION AND CONNECTION
3.4 Swimming Pool Heat Pumps Plumbing
The Swimming Pool Heat Pumps exclusive rated flow titanium heat exchanger requires no special
plumbing arrangements except bypass(please set the flow rate according to the nameplate). The
water pressure drop is less than 10kPa at max. Flow rate. Since there is no residual heat or flame
Temperatures, The unit does not need copper heat sink piping. PVC pipe can be run straight into
the unit.
Location: Connect the unit in the pool pump discharge (return) line downstream of all filter and
pool pumps, and upstream of any chlorinators, ozonators or chemical pumps.
Standard model have slip glue fittings which accept 32mm or 50 mm PVC pipe for
connection to the pool or spa filtration piping. By using a 50 NB to 40NB you can plumb 40NB
Give serious consideration to adding a quick coupler fitting at the unit inlet and outlet to allow easy
draining of unit for winterizing and to provide easier access should servicing be required.
To pool
PVC COUPLER
RECOMMENDED(Provided)
From pump
CONDENSATION
DRAIN
BARB FTG
Condensation: Since the Heat pump cools down the air about 4
, water may condense on
the fins of the horseshoe shaped evaporator. If the relative humidity is very high, this could
be as much as several litres an hour. The water will run down the fins into the basepan and
drain out through the barbed plastic condensation drain fitting on the side of the basepan.
This fitting is designed to accept 20mm clear vinyl tubing which can be pushed on by hand and run
to a suitable drain. It is easy to mistake the condensation for a water leak inside the unit.
NB: Aquick way to verify that the water is condensation is to shut off the unit and keep the pool
pump running. If the water stops running out of the basepan, it is condensation. AN EVEN
QUICKER WAY IS to TEST THE DRAIN WATER FOR CHLORINE - if the is no chlorine
present, then it's condensation.