![Aqua Ultraviolet Viper SL 1200 Watt Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/aqua-ultraviolet/viper-sl-1200-watt/viper-sl-1200-watt_installation-manual_2959172021.webp)
17
AQUA ULTRAVIOLET 42371 AVENIDA ALVARADO, TEMECULA, CA 92590 TEL: 951-296-3480 FAX: 951-296-3490
Quartz Sleeve
Rubber Seal
Rubber Seal
Bushing
Lamp
Union
Flange
A50109
1" Threaded Cap
(2 required)
Remove Lamp
NOTE:
Before re-installing the Unit, the Seals and the Quartz Sleeve will need to be replaced.
WARNING:
Do not allow Viper Unit to be exposed to freezing temperatures without choosing a
winterizing option, severe damage and/or breakage to the Unit, Lamp and/or Quartz Sleeve may
result and are not covered under warranty.
OPTION 1:
If you are going to continually run
water through your unit and it will be exposed
to freezing temperatures be sure to install a 1"
threaded cap (Sold separately) on both sides
of the unit and take all the internal parts inside
(Quartz Sleeve, Rubber Seal Bushings, and
Lamp). Transformer Box may be left outside.
CAUTION:
Always turn off the pump and disconnect the electricity from the unit prior to any
maintenance.
Take These Parts Inside
OPTION 2:
If you shut down your system for winter (no water flow-
ing) remove the lamp and store separately. Disconnect unions or
flanges and take the Viper UV Sterilizer inside.
WINTERIZING: 4",6",8" Plastic and all Stainless Steel Vipers
WINTERIZING
Units may have a Rubber Seal Bushing and/or Rubber Seal.
Stainless Steel units use rubber seal bushings only.
The Cap may be purchased through your
local hardware store or through Aqua UV,
part # A50109.