Take these parts inside
18
8. Twist on the Transformer Cap. Do not over tighten. This is a connection only and is not in
contact with water.
7. Insert the Lamp straight into the Quartz Sleeve. Be careful, inserting the Lamp at an angle, even
a slight angle, can cause a "U" shaped crack in the Quartz Sleeve.
6. Plug the new Lamp flush into the Lamp End Connector. If the Lamp is not plugged in all the way
it may cause damage to the unit and is not covered under warranty. Use Genuine Aqua Ultraviolet
lamps or the warranty is voided.
5. Disconnect the Lamp End Connector from the old Lamp.
4. Slide Lamp out, be careful not to slide the Lamp out at an angle, even a slight angle, this
may cause a “U” shaped crack at the end of the Quartz Sleeve, or possible breakage
of the Lamp. A broken Lamp or Quartz Sleeve are not covered under warranty.
3. Twist off the Transformer Cap.
2. Unscrew the Davis or Hubl Connector located
behind the Transformer Cap, this allows
your Transformer Cap to spin freely.
1. Unplug the Unit from the power source and turn off the pump.
MAINTENANCE
CAUTION: Always turn off the pump and disconnect electricity from the unit prior to
any maintenance.
Changing the Lamp.
9. Tighten the Davis or Hubl Connector located behind the Transformer Cap.
10. FINAL LEAK CHECK: Do not plug the Sterilizer into power yet, turn on the pump, let water run
for 5 minutes and check for leaks.
11. Once a leak test is completed and there are no leaks, plug the Transformer into a GFCI outlet.
Warranty is void if not plugged into a GFCI.
Unscrew Davis Connector
Unscrew Transformer Cap
Davis Connector
TM
Ozone Top
Quartz Cap
Lamp
Transformer Cap
Lamp End Connector
Ozone Bottom
Quartz Cap