TROUBLE SHOOTING LEAKS
Leaks from Quartz Cap / Rubber Seal
Undo Quartz Cap and push Rubber Seal
into the Sterilizer body evenly. Half of the
Rubber Seal will still be in view. Screw on
the Quartz Cap and finger tighten. Do
not use a pipe wrench, pliers or any
other tool. Hand-tighten only. Do not use any
lubricant.
Leaks from the EZ – Twist Top
Check that the O-ring is in the EZ-Twist Top.
Hand tighten EZ-Twist Top until leak stops.
Do not use any lubricant.
Leaks from Center of Quartz Sleeve
The Quartz Sleeve is broken and needs
to be replaced. Neither the broken Quartz
Sleeve nor any damage caused as a result
of a broken Quartz Sleeve is covered
under warranty. Contact your dealer for a
replacement. (See Replacing the Quartz
Sleeve on page 21 and 22).
Ozone Top
Quartz Cap
Leak
Ozone Bottom
Quartz Cap
Leak
EZ Twist Top
Leak
EZ Twist Top
Leak
EZ Twist Top
EZ Twist Top
Ozone Bottom
Quartz Cap
Ozone Top
Quartz Cap
OZONE UV INSTALLATION INSTRUCTIONS
Venturi Installation
Purchase a venturi and a 3/8” hose that is suitable to your application. The venturi should optimally be
installed to inject ozone into the plumbing 3 feet before the UV chamber. If space does not allow for a
distance of 3 feet, inject the ozone as far from the UV Chamber as possible.
TM
TM
INLET
TO OPTIONAL
AIR DRYER
(NOT SUPPLIED)
RETURN
ELBOW
BARB
UNIONS
TRANSFORMER
COMBO UV/OZONE UNIT
VENTURI
(Not Supplied)
3 feet from
UV Chamber