| 19
When the pump is installed outside, we recommend providing simple
protection against the weather (rain, sun etc.).
Implement appropriate measures to attenuate the noise generated
by the pump to avoid damage to the environment. Fastening the
pump to the foundation should be effected exclusively by means
of bolts, threads or dowels, in order to avoid blocking the removal
of the motor unit! Make sure that there is enough space between
the fan cover and the wall, minimum 50 mm. You also need enough
space to permit disassembly of the strainer basket, minimum
210 mm above.
The pump should be installed at water
level or below water level and in a horizontal
position, in order to keep the suction path
as short as possible and to reduce head
loss. The Majestic Master 10 to Majestic
Master 38 is self-priming and should
never be installed more than 2 m above
water level. Make sure that the suction
line is not leaky, otherwise the pump will
prime insufficiently or not at all. We
recommend the installation of check valves
and shut-off valves, depending on the type
of pump or plant. The adhesive bonds at the
suction and pressure lines require more
time to cure, allow at least 12 hours before
starting the pump.
Caution
Caution
D72.50.011-P
50
210
D72.50.012-P
D72.50.013-P