Faults
26 EN
06|2019
7 Faults
Problem:
Pump does not prime or priming time is very long
Possible cause
Solution
Pre-filter is not filled with
water.
Fill to min. height of inlet
connection.
Air is being drawn in.
Suction line has to be free of
leaks; Water level up to middle
of skimmer opening.
Contamination of the
strainer baskets in the
skimmer and pre-filter.
Clean
the
strainer
baskets.
Lid of the pre-filter is not
screwed on tightly.
Tighten.
Suction line very high
above water level.
Install
non-return
valve.
Shut-off valve in suction
and pressure line closed.
Open.
No self-priming pump
being used.
Install a non-return valve at the
suction side.
Problem:
Pump output is not high enough
Possible cause
Solution
Filter dirty
Backwash.
Shut-off valve in the unit closed
Open.
Pipe too long/suction side too
high
Modify.
Suction line leaks - air is drawn
in
Seal.
Problem:
Pump is too loud
Possible cause
Solution
Debris in the pump.
Clean
the
impeller
and
casing.
Содержание AQUA Master Series
Страница 3: ...DE Originalbetriebsanleitung DE AQUA Sandfilteranlage AQ 280 AQ 330 AQ 400 AQ 500 WG23 400 001 P...
Страница 15: ...Beschreibung 06 2019 DE 13 WG26 30 009 P Abb 2...
Страница 38: ......
Страница 51: ...Description 06 2019 EN 13 WG26 30 009 P Fig 2...
Страница 74: ......
Страница 88: ...Description 14 FR 06 2019 WG26 30 009 P Fig 2...
Страница 124: ...Beschrijving 14 NL 06 2019 WG26 30 009 P Afb 2...
Страница 147: ...CS P evod origin ln n vod k obsluze pro CS Za zen pro p skovou filtraci AQUA AQ 280 AQ 330 AQ 400 AQ 500 WG23 400 001 P...
Страница 159: ...Popis 06 2019 CS 13 WG26 30 009 P Obr 2...
Страница 180: ...Technick daje 34 CS 06 2019 500 1 40 30 29 2 13 15 14 9 10 4 5 17 16 18 19 19 31 25 23 21 22 24 WG23 225 001 P Obr 7...
Страница 182: ...36 06 2019...