OPERATION AND MAINTENANCE MANUAL V
]
[
V-1.16
]
AQUA spa
16
7.
Filtering pump control
To access the filtering pump control menu, press FILTER
Pump off
Pump on
On/off Timer settings to cover 24 hours
To set the timer, press ENTER now and follow the instructions provided below
Operation in automatic mode: depending on the data read by the temperature probe, the device
automatically controls when filtering starts up.
See
table A
to know the pre-set daily filtering times
massaging water
jet timer
setting
Press
or
to move to the hour that you wish to change, then press ENTER to enable switching the lights
on at that time. The operating principle is the same as with mechanical timers with tappets. When you have
finished setting all of the times, press ESC to exit programming
Always off at 12
On for the first half hour at 12
On for the second half hour at 12
Access for the entire hour at 12
Table A
(rev.10)
Water temperature
between 3°C and
15°C
Mode
A1
1 hour of daily
filtering
Filtering from 14:00 to 15:00
Water temperature
between 16°C and
20°C
Mode
A2
3 hours of daily
filtering
Filtering from 9:00 to 10:00 – from 12:00 to 13:00 –
from 15:00 to 16:00
Water temperature
between 21°C and
25°C
Mode
A3
6 hours of daily
filtering
Filtering from 8:00 to 9:00 – from 11:00 to 15:00 –
from 19:00 to 20:00
Water temperature
between 26°C and
30°C
Mode
A4
9 hours of daily
filtering
Filtering from 8:00 to 10:00 – from 12:00 to 17:00 –
from 19:00 to 21:00
Water temperature
from 31°C and
higher
Mode
A5
13 hours of daily
filtering
Filtering from 8:00 to 11:00 – from 12:00 to 19:00 –
from 20:00 to 23:00
NOTE: Tcontrol processes an average of the day's temperatures, and changes the MODE at midnight
8.
Frost function
The frost function is an important protection that your Tcontrol runs on its own. With any setting
(filtering on
1
or on
0
or on
T
or on
A
) if the water temperature drops below 3°C your Tcontrol
starts the frost function. AG appears on the display.
This function consists in turning the filtering system on for 3 minutes every hour, day and night. This
procedure allows you to protect the pumps and the hydraulic system and avoid ice from forming
in the pool.