Installation
Procedures

Unit Inspection

Inspect your unit very carefully before
installing. Make sure there has been no
damage to the evaporator fins or there
are no punctures or oil-soaked areas
on the box. This would indicate
damage to the refrigeration system
and should be rejected immediately.

THE UNIT MUST BE TRANSPORTED
IN THE UPRIGHT POSITION AT ALL
TIMES AND MUST NOT BE DROPPED
OR TAILGATED. DAMAGE TO THE
UNIT DURING TRANSPORTATION IS
NOT THE RESPONSIBILITY OF THE
MANUFACTURER.

Unit Location

Once the unit has been inspected and
cleared of any transportation damage,
it is now time to locate the pool
heater. It is very important to
understand the location of the unit for
the best performance. 

A minimum of 18" of clearance
between the evaporator coils and
shrubs, fences, walls, etc. must be
maintained for adequate air intake.

A minimum of 5' of vertical clearance
between the top of the unit and any
roof overhang or other obstructions
must be maintained in order to
prevent the re-circulation of cold air
back into the evaporator coils. This is
to maintain the efficiency of the unit.

A minimum of 24" of clearance
between the front of the unit (access
panel area) and any obstruction must
be maintained to allow maintenance
on the unit when necessary.

The unit should be located on a solid
level surface, a minimum of 36"x 36"
for proper drainage.

Make sure any sprinkler heads are not
directly spraying water on the unit.
While heat pumps are made for an
outdoor environment, they are not
designed to have sprinkler water
constantly spraying them. 

NOTE: This

type of constant watering directly
on the unit can void your warranty.

Condensation drain holes are provided
in all units for adequate removal of
condensation and rainwater. 

ALL

UNITS WILL HAVE CONDENSATION.
THIS SHOULD NOT BE MISTAKEN
FOR A LEAK IN THE UNIT.

Plumbing

Where freezing weather is
encountered, the detachable
connection/union (NOT provided) must
be utilized immediately adjacent to the
heater to facilitate servicing and
draining of the heat exchanger.

Draining is necessary to prevent
damage to the condenser shell and
coil due to the expansion of
freezing water.

The minimum water circulation
capacity flowing through the pool
heater is 25 gallons per minute and the
maximum capacity is 80 gallons per
minute.

Do not install a water shutoff valve in
the piping from the outlet of the pool
heater to the pool or tub. However,
a check valve that does not include a
shut-off feature may be installed for
convenience during servicing.

A check valve or Hartford Loop is
recommended between the unit and

NOTICE

2

Operating Instructions

a chlorinator. Failure to do so will void
the warranty.

Figure 1 shows the recommended
installation layout.

Basic Heat Pump
Operation

Electrical Connections

All wiring and
electrical

connections must be performed by a
qualified electrician. Installations must
be in accordance with local and
national codes.

Overheating, short-
circuiting and fire

damage will result from inadequate
wiring.

All units are equipped with an
electrical wiring schematic inside the
electrical panel. If this is missing, please
contact the factory at 1-877-278-2797
to obtain one. 

All units are to be wired for 230 VAC,
1 phase. This unit requires a dedicated
30-amp breaker or time delay fuse.

Pool Heater is to be installed in
accordance with Article 680 of the
National Electrical Code (NEC), NFPA
70, and within the requirements of all
local codes having jurisdiction. 

Connecting to Remote
Systems

This Pool Heater is compatible with 
2-wire remote systems. Figure 2 shows
where to connect the remote system to
the Temperature Controller.

!

CAUTION

!

WARNING

www.aquaprosystems.com

COLD WATER
IN FROM POOL

FILTER

POOL

HEATER

CHECK VALVE

CHLORINATOR

WARM WATER
OUTLET TO POOL

IN

OUT

UNIONS

Figure 1 - Recommended installation layout

Содержание PRO400

Страница 1: ...tal damage during the early months of pregnancy Pregnant or possibly pregnant women should limit pool or tub water temperatures to 100ºF 38ºC Alcohol drugs or medication should not be used before or during pool or tub use since their use may lead to unconsciousness with the possibility of drowning Obese persons and persons with a medical history of heart disease low or high blood pressure circulat...

Страница 2: ...FOR A LEAK IN THE UNIT Plumbing Where freezing weather is encountered the detachable connection union NOT provided must be utilized immediately adjacent to the heater to facilitate servicing and draining of the heat exchanger Draining is necessary to prevent damage to the condenser shell and coil due to the expansion of freezing water The minimum water circulation capacity flowing through the pool...

Страница 3: ...tup Water Temperature Set Point Temperature set point range is 45 F to 107 F Rotating the thermostat knob clockwise will increase the temperature set point while rotating counterclockwise will decrease the temperature set point A floating thermometer may be placed in the pool or spa to monitor water temperature To initially calibrate the thermostat to the desired set point turn the thermostat knob...

Страница 4: ...or service and turn off the power to the heater to keep the cycling from damaging the compressor 4 Operating Instructions www aquaprosystems com Condensation All heat pump pool heaters will have condensation It is typical to have as much as 6 8 gallons of condensation or water per hour during a warm humid day Do not mistake this for a leak If you are not sure the water is a leak or is condensation...

Страница 5: ...s on how long an implied warranty lasts or do not allow the exclusions or limitations of incidental or consequential damages so the above limitations might not apply to you This limited warranty gives you specific legal rights and you may also have other legal rights which vary from state to state In no event whether as a result of breach of contract warranty tort including negligence or otherwise...

Страница 6: ...6 Manual de Instrucciones Notes Notas www aquaprosystems com ...

Страница 7: ...muerte o lesiones graves Precaución indica una situación potencialmente peligrosa que si no se evita puede dar como resultado lesiones leves o moderadas Aviso indica información importante que si no se cumple puede causar daños al equipo AVISO PRECAUCION ADVERTENCIA El agua de una piscina o tina nunca debería exceder los 104ºF 40ºC El agua a una temperatura que exceda los 104ºF 40ºC no se consider...

Страница 8: ...alación Inspección de la unidad Inspeccione la unidad muy cuidadosamente antes de instalarla Asegúrese de que no han habido daños en las aletas de evaporación y que no hay pinchaduras ni áreas empapadas de aceite en la caja Esto indicaría un daño en el sistema de refrigeración y debería rechazarse inmediatamente LA UNIDAD DEBE TRANSPORTARSE EN POSICIÓN VERTICAL EN TODO MOMENTO Y NO DEBE DEJARSE CA...

Страница 9: ...No instale una válvula de corte de agua en las tuberías desde la salida del calentador de piscina hasta la piscina o tina Sin embargo se podrá instalar una válvula de retención que no incluya un dispositivo de corte para más practicidad durante el servicio Se recomienda una válvula de retención o Hartford Loop entre la unidad y un clorador El no hacer eso anulará la garantía La Figura 1 muestra la...

Страница 10: ...jar la bomba del filtro funcionando y ver si el agua deja de correr Si no ve más agua entonces el agua que había originalmente era condensación Cubiertas para piscinas Se ha comprobado que las cubiertas para piscinas reducen en gran medida la pérdida de calor en la piscina y ahorrarán un máximo de 50 a 60 en sus facturas de calefacción Durante el comienzo de la temporada de verano y al final de la...

Страница 11: ...igüe la causa de este código Una vez que haya hecho todo lo recomendado entonces llame a la fábrica para solicitar un servicio La unidad no está funcionando Verifique la luz de corriente Verifique que el disyuntor esté en la posición correcta Asegúrese de que el sistema de filtrado esté encendido Asegúrese de que el termostato está más alto que la temperatura del agua de la piscina Asegúrese de qu...

Страница 12: ...nes sobre la duración de las garantías implícitas o no permiten la exclusión ni la limitación de daños incidentales o consecuentes por lo tanto es posible que las limitaciones anteriores no se apliquen en su caso Esta garantía limitada le proporciona derechos legales específicos y también puede tener otros derechos legales que varían de un estado a otro Bajo ningún concepto ya sea por incumplimien...

Отзывы: