requirements.

TESTING AND CERTIFICATION

All suction inlet covers must comply with ASME/ANSI A112.19.8B specifications for suction fittings for use in swimming pools, spas and 
whirlpool bathtub applications. The product must be tested for compliance with the standards and the certification must be included with 
the components.
Single or Multiple Pump Circulation Systems must be provided with a minimum of 2 (two) suction inlets of the approved type.
Do not install multiple pumps in one hydraulic circuit. The pump is not designed to accept output flow from another pump. Do not allow 
water to back flow through the pump. Water flowing in the discharge and out the suction during an upset condition can cause the motor 
to rotate backwards. Never attempt to start the pump if the shaft is rotating due to a hydraulic turbine action. This could cause pump to 
operate in reverse and damage internal components.

OUTLETS PER PUMP

Provide at least two hydraulically balanced main drains, with covers for each swimming pool pump suction line. The centers of the main 
drains suction fitting must be at least 3 ft. apart (see Figure 2). The system must be built so that it cannot operate with the pump drawing 
water from only one main drain. Two main drains must be connected to the pump whenever it is running. If two main drains run into a 
single suction line, the single suction line can be equipped with a single valve that shuts off both main drains from the pump. 

A valve in 

each suction line is not allowed.
PIPING

Use at least 1-1/2” (38mm) pipe (use 2”(51mm) pipe if possible). Increase size if a long run is needed. To avoid strains on the pump, 
support both suction and discharge pipes independently. Place these supports near the pump. 
To avoid a strain left by a gap at the last connection, start all piping at the pump and run pipe away from the pump.
To avoid airlocking, slope suction pipe slightly upward toward the pump.
NOTICE: To prevent flooding when removing pump for service, all flooded suction systems must have gate valves in suction and discharge 
pipes.
DV FLO pump includes 1 1/2” female NPT, or 2” slip-fit connections.
APEX Series pumps include 2” female NPT connections.

 

Figure 4 - DV FLO

Содержание APEX Series

Страница 1: ...mp We strive to continually create quality pool products Visit us online to see our full line of products available Thank you OWNER S MANUAL DV FLO PUMP APEX SERIES Questions problems missing parts Before returning to the store call Customer Service 8 a m 6 p m EST Monday Friday 1 877 278 2797 ECOAQUAPRO COM ...

Страница 2: ...5 WARNING This product may contain chemicals known to the State of California to cause cancer and birth defects or other reproductive harm Wash hands after handling DANGER To reduce the risk of injury do not permit children to use this product unless they are closely supervised at all times WARNING Risk of electrical shock Connect only to a branch circuit protected by a ground fault circuit interr...

Страница 3: ...re secure Many local codes require primer with a purple tracer to verify primer use Consider climatic conditions when applying adhesives Atmospheric conditions with high humidity will make the adhesive action of certain glues less effective Follow the manufacturer s instructions POOL SAFETY GUIDELINES RESPONSIBLE ADULT SUPERVISION Constant and responsible adult supervision is mandatory in the pool...

Страница 4: ...d of suitable size 2 Avoid connecting an elbow directly into the pump inlet A length of straight pipe will allow proper entry of the water to the pump 3 Slope horizontal runs upward to the pump to prevent trapping air 4 Use independent piping supports to reduce strain on the pump 5 Keep as much of the suction line as possible below the water level to reduce priming time 6 Install valves and unions...

Страница 5: ...ually check the system for leaks Figure 3 Clamp rings POOL PUMP SUCTION REQUIREMENTS WARNING Pump suction is hazardous and can trap drown or disembowel bathers Do not use or operate swimming pools or spas if a suction outlet cover is missing broken or loose Follow the guidelines below for a pump installation which minimizes risk to users of pools and spas DANGER Ground the motor before connecting ...

Страница 6: ...ns with covers for each swimming pool pump suction line The centers of the main drains suction fitting must be at least 3 ft apart see Figure 2 The system must be built so that it cannot operate with the pump drawing water from only one main drain Two main drains must be connected to the pump whenever it is running If two main drains run into a single suction line the single suction line can be eq...

Страница 7: ...have a qualified electrician inspect and repair the electrical system Verify that the supply voltage matches the nameplate voltage Incorrect voltage can cause fire or seriously damage the motor and voids the warranty VOLTAGE CHANGING DEFAULT SETTING Voltage at the motor must be within 10 of the motor nameplate rated voltage or the motor may overheat causing overload tripping and reduced component ...

Страница 8: ...al or National Electrical Code requirements Permanently ground motor Use green ground terminal provided under motor canopy or access plate use size and type wire required by code Connect motor ground terminal to electrical service ground Connect a No 8 AWG 8 4 sq mm solid copper bonding wire to the bonding lug provided on the motor housing and to all metal parts of the swimming pool spa or hot tub...

Страница 9: ...ure white cord strain relief part E 6 Reinstall box cover 115V WITH 16 GAUGE POWER CORD 1 Remove long hex adapter part A off pump 2 Remove pump box cover four screws included with pump 3 Unscrew and realign the brass bridge part H and brass washers part I to match 115V wiring diagram see figure 5 4 Run the 16 gauge cord through the rubber cone gasket part C Insert cone gasket into black hex cap pa...

Страница 10: ...If unsure how to do this or if this is confusing consult a licensed electrician Use the load circuit breaker as the master on off switch Install a Ground Fault Circuit Interrupter GFCI in circuit it will sense a short circuit to ground and disconnect power before it becomes dangerous to pool users For size of GFCI required and test procedures see GFCI manufacturer s instruction In case of power ou...

Страница 11: ...n line If the pump does not prime make sure that all valves are open and the suction pipe is submerged Verify there are no leaks in suction lines See Troubleshooting Guide for further assistance Maintenance All of our pumps are shipped from the factory with DANGER and or WARNING labels already on the pump These labels contain a series of basic yet extremely important safety messages for the user a...

Страница 12: ...sconnect power before working on pump or motor 1 Pump down water level below all inlets to the pool Risk of electric shock Can shock burn or kill To avoid dangerous or fatal electrical shock hazard turn OFF power to motor before draining pump 2 Remove trap cover and use low pressure air to blow accumulated water from the piping system Never use high pressure air to purge system 3 Cap inlet piping ...

Страница 13: ...e 2 To avoid condensation corrosion damage allow ventilation do not wrap system in plastic 3 Use a 40 propylene glycol 60 water solution to protect pump to 50 F 46 C STARTUP FOR WINTERIZED EQUIPMENT 1 Remove any temporary weather protection placed around system for shutdown 2 Follow filter manufacturer s instructions for reactivation of the filter 3 Inspect all electrical wiring for damage or dete...

Страница 14: ...y vacuum release system SVRS devices are not compatible with the installation of check valves If the pool has an SVRS device be sure to confirm that it will continue to safely operate when any check valves are installed FAILURE TO PUMP CLOGGED PIPE TRAP IMPELLER WORN IMPELLER 5 Make sure the suction trap is not clogged if it is clean the trap and the strainer See Maintenance section 6 Make sure th...

Страница 15: ... REPLACEMENT PARTS OR TECHNICAL ASSISTANCE PLEASE CALL 1 888 658 1594 Please provide the following information Model number Serial number Part description and number as shown in parts list 1 19 15 14 9 6 17 7 16 10 5 3 2 18 20 21 12 8a 13 11 4 8b 22 Figure 13 APEX Series Pump Replacement Parts ...

Страница 16: ...16 Replacement Parts continued Figure 13 continued APEX Series Pump Replacement Parts ...

Страница 17: ...stance Replacement Parts continued FOR REPLACEMENT PARTS OR TECHNICAL ASSISTANCE PLEASE CALL 1 888 658 1594 Please provide the following information Model number Serial number Part description and number as shown in parts list Figure 14 DV FLO Pump Replacement Parts ...

Страница 18: ...18 Replacement Parts continued Figure 14 continued DV FLO Pump Replacement Parts ...

Страница 19: ...ou may also have other legal rights which vary from state to state In no event whether as a result of breach of contract warranty tort including negligence or otherwise shall the manufacturer or its suppliers be liable for any special consequential incidental or penal damages including but not limited to loss of profit or revenues loss of use of the products or any associated equipment damage to a...

Страница 20: ...Questions problems missing parts Call Customer Service 8 a m 6 p m EST Monday Friday 1 877 278 2797 ECOAQUAPRO COM Retain this manual for future use ...