Aqua PRO APEX Series Скачать руководство пользователя страница 11

 11 ECOAQUAPRO.COM
 

 

Please contact 1-877-278-2797 for further assistance.

DANGER:

 

 Risk of fire and burns. Motors run at high temperatures. To reduce the risk of fire, do not allow leaves, debris, or 

foreign matter to collect around the pump motor. To avoid burns when handling the motor, let it cool for 20 minutes before trying 
to work on it. An automatic internal cutoff switch protects the motor from heat damage during operation. 

DANGER:

 

 Hazardous Suction. Can trap hair or body, causing severe injury or death. Do not block suction. Keep small children 

under close adult supervision at all times.

NOTE:

 Do NOT run the pump dry! It will void your warranty and may damage seals, causing leakage and flooding. 

Fill the pump with water before starting the motor.

BEFORE REMOVING THE TRAP COVER

1. CLOSE GATE VALVES in suction and discharge pipes.
2. RELEASE ALL PRESSURE from pump and piping system.
If the pump is being pressure tested, be sure pressure has been released before removing the trap cover.

PRIMING PUMP

Release all pressure from the filter, pump, and piping system; see the filter owner’s manual. In a flooded suction system (water source 
higher than pump), pump will prime automatically when suction and discharge valves are opened. If the pump is located above the normal 
pool water level, remove ring and cover assembly and slowly fill the basket and pump with water. Clean and inspect the O-ring and reinstall 
on the trap. Replace the ring and cover assembly and rotate clockwise to tighten the cover (see Figure 3).
The clamp ring must engage with the pump body. Push down and rotate until the internal stops are felt. Properly aligned tabs shown above 
in Figure 3. Ensure the lid is securely clamped. Failure to tighten clamp ring as indicated will reduce product strength, resulting in failure of 
components, and bodily injury.

NOTE:

 Pump prime time will depend on vertical distance and length of suction line. If the pump does not prime, make sure that all valves are 

open and the suction pipe is submerged. Verify there are no leaks in suction lines. See Troubleshooting Guide for further assistance.

Maintenance

All of our pumps are shipped from the factory with DANGER and/or WARNING labels already on the pump. These labels contain a series 
of basic, yet extremely important safety messages for the user and bystander. Regardless of how well these labels are attached or how 
scratch resistant or wear-resistant they may be, it is possible that, in time, the wording may become illegible with normal use. Whenever 
you are repairing the pump, performing routine maintenance, or have the opportunity to inspect the pump, make sure the label is readable. 
If the label is not legible, replace the label with an adhesive version that is available at no charge by calling 1-888-658-1594. The unit must 
be connected only to a supply circuit that is protected by a ground-fault circuit-interrupter (GFCI). Such a GFCI should be provided by the 
installer and should be tested on a routine basis. To test the GFCI, push the test button. The GFCI should interrupt power. Push the reset 
button. Power should be restored. If the GFCI fails to operate in this manner, the GFCI is defective. If the GFCI interrupts power to the pump 
without the test button being pushed, a ground current is flowing, indicating the possibility of an electric shock. Do not use this pump. 
Disconnect the pump and have the problem corrected by a qualified service representative before using.
Use only parts supplied by the manufacturer. Similar looking parts may not have sufficient strength for safe operation.
The only routine maintenance needed is inspection/cleaning of the strainer basket. Debris or trash that collects in the basket will choke off 
water flow through the pump.

BEFORE ATTEMPTING TO CLEAN THE BASKET

A. Stop the pump, disconnect power at its source, lock out power, place a tag on the dedicated GFCI circuit breaker indicating the power is 
to remain OFF, close valves in suction and discharge, and release pressure from the system.

Содержание APEX Series

Страница 1: ...mp We strive to continually create quality pool products Visit us online to see our full line of products available Thank you OWNER S MANUAL DV FLO PUMP APEX SERIES Questions problems missing parts Before returning to the store call Customer Service 8 a m 6 p m EST Monday Friday 1 877 278 2797 ECOAQUAPRO COM ...

Страница 2: ...5 WARNING This product may contain chemicals known to the State of California to cause cancer and birth defects or other reproductive harm Wash hands after handling DANGER To reduce the risk of injury do not permit children to use this product unless they are closely supervised at all times WARNING Risk of electrical shock Connect only to a branch circuit protected by a ground fault circuit interr...

Страница 3: ...re secure Many local codes require primer with a purple tracer to verify primer use Consider climatic conditions when applying adhesives Atmospheric conditions with high humidity will make the adhesive action of certain glues less effective Follow the manufacturer s instructions POOL SAFETY GUIDELINES RESPONSIBLE ADULT SUPERVISION Constant and responsible adult supervision is mandatory in the pool...

Страница 4: ...d of suitable size 2 Avoid connecting an elbow directly into the pump inlet A length of straight pipe will allow proper entry of the water to the pump 3 Slope horizontal runs upward to the pump to prevent trapping air 4 Use independent piping supports to reduce strain on the pump 5 Keep as much of the suction line as possible below the water level to reduce priming time 6 Install valves and unions...

Страница 5: ...ually check the system for leaks Figure 3 Clamp rings POOL PUMP SUCTION REQUIREMENTS WARNING Pump suction is hazardous and can trap drown or disembowel bathers Do not use or operate swimming pools or spas if a suction outlet cover is missing broken or loose Follow the guidelines below for a pump installation which minimizes risk to users of pools and spas DANGER Ground the motor before connecting ...

Страница 6: ...ns with covers for each swimming pool pump suction line The centers of the main drains suction fitting must be at least 3 ft apart see Figure 2 The system must be built so that it cannot operate with the pump drawing water from only one main drain Two main drains must be connected to the pump whenever it is running If two main drains run into a single suction line the single suction line can be eq...

Страница 7: ...have a qualified electrician inspect and repair the electrical system Verify that the supply voltage matches the nameplate voltage Incorrect voltage can cause fire or seriously damage the motor and voids the warranty VOLTAGE CHANGING DEFAULT SETTING Voltage at the motor must be within 10 of the motor nameplate rated voltage or the motor may overheat causing overload tripping and reduced component ...

Страница 8: ...al or National Electrical Code requirements Permanently ground motor Use green ground terminal provided under motor canopy or access plate use size and type wire required by code Connect motor ground terminal to electrical service ground Connect a No 8 AWG 8 4 sq mm solid copper bonding wire to the bonding lug provided on the motor housing and to all metal parts of the swimming pool spa or hot tub...

Страница 9: ...ure white cord strain relief part E 6 Reinstall box cover 115V WITH 16 GAUGE POWER CORD 1 Remove long hex adapter part A off pump 2 Remove pump box cover four screws included with pump 3 Unscrew and realign the brass bridge part H and brass washers part I to match 115V wiring diagram see figure 5 4 Run the 16 gauge cord through the rubber cone gasket part C Insert cone gasket into black hex cap pa...

Страница 10: ...If unsure how to do this or if this is confusing consult a licensed electrician Use the load circuit breaker as the master on off switch Install a Ground Fault Circuit Interrupter GFCI in circuit it will sense a short circuit to ground and disconnect power before it becomes dangerous to pool users For size of GFCI required and test procedures see GFCI manufacturer s instruction In case of power ou...

Страница 11: ...n line If the pump does not prime make sure that all valves are open and the suction pipe is submerged Verify there are no leaks in suction lines See Troubleshooting Guide for further assistance Maintenance All of our pumps are shipped from the factory with DANGER and or WARNING labels already on the pump These labels contain a series of basic yet extremely important safety messages for the user a...

Страница 12: ...sconnect power before working on pump or motor 1 Pump down water level below all inlets to the pool Risk of electric shock Can shock burn or kill To avoid dangerous or fatal electrical shock hazard turn OFF power to motor before draining pump 2 Remove trap cover and use low pressure air to blow accumulated water from the piping system Never use high pressure air to purge system 3 Cap inlet piping ...

Страница 13: ...e 2 To avoid condensation corrosion damage allow ventilation do not wrap system in plastic 3 Use a 40 propylene glycol 60 water solution to protect pump to 50 F 46 C STARTUP FOR WINTERIZED EQUIPMENT 1 Remove any temporary weather protection placed around system for shutdown 2 Follow filter manufacturer s instructions for reactivation of the filter 3 Inspect all electrical wiring for damage or dete...

Страница 14: ...y vacuum release system SVRS devices are not compatible with the installation of check valves If the pool has an SVRS device be sure to confirm that it will continue to safely operate when any check valves are installed FAILURE TO PUMP CLOGGED PIPE TRAP IMPELLER WORN IMPELLER 5 Make sure the suction trap is not clogged if it is clean the trap and the strainer See Maintenance section 6 Make sure th...

Страница 15: ... REPLACEMENT PARTS OR TECHNICAL ASSISTANCE PLEASE CALL 1 888 658 1594 Please provide the following information Model number Serial number Part description and number as shown in parts list 1 19 15 14 9 6 17 7 16 10 5 3 2 18 20 21 12 8a 13 11 4 8b 22 Figure 13 APEX Series Pump Replacement Parts ...

Страница 16: ...16 Replacement Parts continued Figure 13 continued APEX Series Pump Replacement Parts ...

Страница 17: ...stance Replacement Parts continued FOR REPLACEMENT PARTS OR TECHNICAL ASSISTANCE PLEASE CALL 1 888 658 1594 Please provide the following information Model number Serial number Part description and number as shown in parts list Figure 14 DV FLO Pump Replacement Parts ...

Страница 18: ...18 Replacement Parts continued Figure 14 continued DV FLO Pump Replacement Parts ...

Страница 19: ...ou may also have other legal rights which vary from state to state In no event whether as a result of breach of contract warranty tort including negligence or otherwise shall the manufacturer or its suppliers be liable for any special consequential incidental or penal damages including but not limited to loss of profit or revenues loss of use of the products or any associated equipment damage to a...

Страница 20: ...Questions problems missing parts Call Customer Service 8 a m 6 p m EST Monday Friday 1 877 278 2797 ECOAQUAPRO COM Retain this manual for future use ...

Отзывы: