Aqua PRO APEX Series Скачать руководство пользователя страница 2

 2
 

Table of Contents

Table of Contents  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Safety Information  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

General Safety Guidelines  . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Pool Safety Guidelines  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Electrical  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Voltage, Grounding/Bonding. . . . . . . . . . . . . . . . . . . . . . . . . . 7

Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Troubleshooting  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Replacement Parts  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Warranty Information  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Safety Information

DESCRIPTION

These self priming pool pumps are for high efficiency, and easy 
maintenance, with an oversized strainer basket. It is constructed 
of durable thermoplastic for years of trouble free service. These 
swimming pool pumps are designed for use with permanently 
installed swimming pools and spas only. Do not use with storable 
pools.

UNPACKING

After unpacking the unit, carefully inspect for any damage that may 
have occurred during transit. Check for loose, missing or damaged 
parts.

SAFETY GUIDELINES

This manual contains information that is very important to know and 
understand. This information is provided for SAFETY and to PREVENT 
EQUIPMENT PROBLEMS.
As a user, you are important to us. Thus, one copy of the Operating 
Instructions and Parts Manual is included with each pump shipped 
from our factory. This manual contains important sections relative 
to user safety, use, maintenance, warranty, etc. It is a good idea to 
ask for extra copies for other installers/users. Extra copies, free of 
charge, are available.
Do not use pump for any purpose other than pool/spa application. 
Components have not been designed for other applications. Severe 
pump failure, may result. Any unapproved use will void warranty.

CALIFORNIA PROPOSITION 65

WARNING:

 This product may contain chemicals known to 

the State of California to cause cancer and birth defects or 
other reproductive harm. Wash hands after handling.

DANGER:

 To reduce the risk of injury, do not permit 

children to use this product unless they are closely 
supervised at all times.

WARNING:

 Risk of electrical shock. Connect only to a 

branch circuit protected by a ground-fault circuit-interrupter 
(GFCI). Contact a qualified electrician if you cannot verify 
that the receptacle is protected by a GFCI. The unit must 
be connected only to a supply circuit that is protected 
by a ground-fault circuit-interrupter (GFCI). Such a GFCI 
should be provided by the installer and should be tested 
on a routine basis. To test the GFCI, push the test button. 
The GFCI should interrupt power. Push the reset button. 
Power should be restored. If the GFCI fails to operate in 
this manner, the GFCI is defective. If the GFCI interrupts 
power to the pump without the test button being pushed, 
a ground current is flowing, indicating the possibility of an 
electric shock. Do not use this pump. Disconnect the pump 
and have the problem corrected by a qualified service 
representative before using.

CAUTION:

 This pump is for use with permanently- 

installed pools and may also be used with hot tubs and 
spas if so marked. Do not use with storable pools. A 
permanently- installed pool is constructed in or on the 
ground or in a building such that it cannot be readily 
disassembled for storage. A storable pool is constructed so 
that it is capable of being readily disassembled for storage 
and reassembled to its original integrity. Do not install 
within an outer enclosure or beneath the skirt of a hot tub 
or spa.

NOTICE:

 PLEASE SAVE THESE INSTRUCTIONS.

Содержание APEX Series

Страница 1: ...mp We strive to continually create quality pool products Visit us online to see our full line of products available Thank you OWNER S MANUAL DV FLO PUMP APEX SERIES Questions problems missing parts Before returning to the store call Customer Service 8 a m 6 p m EST Monday Friday 1 877 278 2797 ECOAQUAPRO COM ...

Страница 2: ...5 WARNING This product may contain chemicals known to the State of California to cause cancer and birth defects or other reproductive harm Wash hands after handling DANGER To reduce the risk of injury do not permit children to use this product unless they are closely supervised at all times WARNING Risk of electrical shock Connect only to a branch circuit protected by a ground fault circuit interr...

Страница 3: ...re secure Many local codes require primer with a purple tracer to verify primer use Consider climatic conditions when applying adhesives Atmospheric conditions with high humidity will make the adhesive action of certain glues less effective Follow the manufacturer s instructions POOL SAFETY GUIDELINES RESPONSIBLE ADULT SUPERVISION Constant and responsible adult supervision is mandatory in the pool...

Страница 4: ...d of suitable size 2 Avoid connecting an elbow directly into the pump inlet A length of straight pipe will allow proper entry of the water to the pump 3 Slope horizontal runs upward to the pump to prevent trapping air 4 Use independent piping supports to reduce strain on the pump 5 Keep as much of the suction line as possible below the water level to reduce priming time 6 Install valves and unions...

Страница 5: ...ually check the system for leaks Figure 3 Clamp rings POOL PUMP SUCTION REQUIREMENTS WARNING Pump suction is hazardous and can trap drown or disembowel bathers Do not use or operate swimming pools or spas if a suction outlet cover is missing broken or loose Follow the guidelines below for a pump installation which minimizes risk to users of pools and spas DANGER Ground the motor before connecting ...

Страница 6: ...ns with covers for each swimming pool pump suction line The centers of the main drains suction fitting must be at least 3 ft apart see Figure 2 The system must be built so that it cannot operate with the pump drawing water from only one main drain Two main drains must be connected to the pump whenever it is running If two main drains run into a single suction line the single suction line can be eq...

Страница 7: ...have a qualified electrician inspect and repair the electrical system Verify that the supply voltage matches the nameplate voltage Incorrect voltage can cause fire or seriously damage the motor and voids the warranty VOLTAGE CHANGING DEFAULT SETTING Voltage at the motor must be within 10 of the motor nameplate rated voltage or the motor may overheat causing overload tripping and reduced component ...

Страница 8: ...al or National Electrical Code requirements Permanently ground motor Use green ground terminal provided under motor canopy or access plate use size and type wire required by code Connect motor ground terminal to electrical service ground Connect a No 8 AWG 8 4 sq mm solid copper bonding wire to the bonding lug provided on the motor housing and to all metal parts of the swimming pool spa or hot tub...

Страница 9: ...ure white cord strain relief part E 6 Reinstall box cover 115V WITH 16 GAUGE POWER CORD 1 Remove long hex adapter part A off pump 2 Remove pump box cover four screws included with pump 3 Unscrew and realign the brass bridge part H and brass washers part I to match 115V wiring diagram see figure 5 4 Run the 16 gauge cord through the rubber cone gasket part C Insert cone gasket into black hex cap pa...

Страница 10: ...If unsure how to do this or if this is confusing consult a licensed electrician Use the load circuit breaker as the master on off switch Install a Ground Fault Circuit Interrupter GFCI in circuit it will sense a short circuit to ground and disconnect power before it becomes dangerous to pool users For size of GFCI required and test procedures see GFCI manufacturer s instruction In case of power ou...

Страница 11: ...n line If the pump does not prime make sure that all valves are open and the suction pipe is submerged Verify there are no leaks in suction lines See Troubleshooting Guide for further assistance Maintenance All of our pumps are shipped from the factory with DANGER and or WARNING labels already on the pump These labels contain a series of basic yet extremely important safety messages for the user a...

Страница 12: ...sconnect power before working on pump or motor 1 Pump down water level below all inlets to the pool Risk of electric shock Can shock burn or kill To avoid dangerous or fatal electrical shock hazard turn OFF power to motor before draining pump 2 Remove trap cover and use low pressure air to blow accumulated water from the piping system Never use high pressure air to purge system 3 Cap inlet piping ...

Страница 13: ...e 2 To avoid condensation corrosion damage allow ventilation do not wrap system in plastic 3 Use a 40 propylene glycol 60 water solution to protect pump to 50 F 46 C STARTUP FOR WINTERIZED EQUIPMENT 1 Remove any temporary weather protection placed around system for shutdown 2 Follow filter manufacturer s instructions for reactivation of the filter 3 Inspect all electrical wiring for damage or dete...

Страница 14: ...y vacuum release system SVRS devices are not compatible with the installation of check valves If the pool has an SVRS device be sure to confirm that it will continue to safely operate when any check valves are installed FAILURE TO PUMP CLOGGED PIPE TRAP IMPELLER WORN IMPELLER 5 Make sure the suction trap is not clogged if it is clean the trap and the strainer See Maintenance section 6 Make sure th...

Страница 15: ... REPLACEMENT PARTS OR TECHNICAL ASSISTANCE PLEASE CALL 1 888 658 1594 Please provide the following information Model number Serial number Part description and number as shown in parts list 1 19 15 14 9 6 17 7 16 10 5 3 2 18 20 21 12 8a 13 11 4 8b 22 Figure 13 APEX Series Pump Replacement Parts ...

Страница 16: ...16 Replacement Parts continued Figure 13 continued APEX Series Pump Replacement Parts ...

Страница 17: ...stance Replacement Parts continued FOR REPLACEMENT PARTS OR TECHNICAL ASSISTANCE PLEASE CALL 1 888 658 1594 Please provide the following information Model number Serial number Part description and number as shown in parts list Figure 14 DV FLO Pump Replacement Parts ...

Страница 18: ...18 Replacement Parts continued Figure 14 continued DV FLO Pump Replacement Parts ...

Страница 19: ...ou may also have other legal rights which vary from state to state In no event whether as a result of breach of contract warranty tort including negligence or otherwise shall the manufacturer or its suppliers be liable for any special consequential incidental or penal damages including but not limited to loss of profit or revenues loss of use of the products or any associated equipment damage to a...

Страница 20: ...Questions problems missing parts Call Customer Service 8 a m 6 p m EST Monday Friday 1 877 278 2797 ECOAQUAPRO COM Retain this manual for future use ...

Отзывы: