11
11. Remove the riser hose and elbow.
12. Remove the strainer cover from the front of the
pump. To do this, firmly hold the motor with one
hand and pull the cover away from the motor.
13. Remove the impeller cover. To unlock it, turn
it clockwise (Aquatica 160) or anti-clockwise
(Aquatica 240) and carefully pull away.
14. Grasp the impeller blades and gently pull the
impeller from the impeller chamber. Take care not
to break the impeller shaft.
A pair of clean needle nose pliers can make this
step easier.
15. Clean impeller and shaft under warm running
water. Do not use soap or detergent. Remove the
rubber end caps and ceramic shaft and run clean
water through the hole in the centre of the impeller.
Be careful not to lose the smaller parts.
16. Use an Aqua One double ended pipe brush to
clean the impeller chamber thoroughly. (refer to
diagram below)
DO NOT USE AN ABRASIVE MATERIAL TO
CLEAN THE PUMP COMPONENTS.
17. Please ensure the impeller chamber is free
from debris before reassembling the pump, failure
to do so could damage your pump.
18. Ensure both rubber end caps are in the correct
position. If they do not come out when the impeller
is removed one should be in the impeller chamber
and the other in the impeller cover. Failure to
position them correctly may result in your pump
being damaged.
Disposal of used Electrical & Electronic Equipment
(Applicable in the European Union and other
European countries with separate collection
systems)
This symbol on the product or on its
packaging indicates that the product
must not be disposed of with normal
household waste. Instead, it is your
responsibility to dispose of your waste
equipment by arranging to return it to a designated
collection point for the recycling of waste electrical
and electronic equipment. By separating and recycling
your waste equipment at the time of disposal you will
help to conserve natural resources and ensure that the
equipment is recycled in a manner that protects human
health and the environment. For more information
about recycling this product, please contact your local
city office, your household waste disposal service or
the shop where you have purchased the product.
Impeller
Chamber
19. Do not force the unit back together as the
ceramic shaft may break. If it does not reassemble
easily check the position of the rubber end caps,
ceramic shaft and impeller.
20. (Aquatica 240 only) Check the Prefilter
Sponge. Rinse under tap water to remove any
built up which may have accumulated on it. If the
sponge shows signs of deterioration replace it.
21. Reassemble the pump in reverse order. We
recommend that an aquarium safe lubricant such
as AquaLube is used to lubricate the O-ring on the
impeller cover.
22. Replace the filter pump in the filter chamber.
Re-connect the duckbill.
23. Replace glass lid, lid flaps and light.
24. Ensure your hands and plugs are dry. Plug in
the pump, light and heater.
Содержание Aquatica 160