background image

11

11. Remove the riser hose and elbow.

12. Remove the strainer cover from the front of the 

pump. To do this, firmly hold the motor with one 

hand and pull the cover away from the motor.

13. Remove the impeller cover. To unlock it, turn 
it clockwise (Aquatica 160) or anti-clockwise 
(Aquatica 240) and carefully pull away.

14. Grasp the impeller blades and gently pull the 
impeller from the impeller chamber. Take care not 
to break the impeller shaft.

A pair of clean needle nose pliers can make this 
step easier.
 
15. Clean impeller and shaft under warm running 
water. Do not use soap or detergent. Remove the 
rubber end caps and ceramic shaft and run clean 
water through the hole in the centre of the impeller.

Be careful not to lose the smaller parts. 

16. Use an Aqua One double ended pipe brush to 
clean the impeller chamber thoroughly. (refer to 
diagram below)

DO NOT USE AN ABRASIVE MATERIAL TO 
CLEAN THE PUMP COMPONENTS.

     

17. Please ensure the impeller chamber is free 
from debris before reassembling the pump, failure 
to do so could damage your pump.

18. Ensure both rubber end caps are in the correct 
position. If they do not come out when the impeller 
is removed one should be in the impeller chamber 
and the other in the impeller cover. Failure to 
position them correctly may result in your pump 
being damaged.

Disposal of used Electrical & Electronic Equipment 
(Applicable in the European Union and other 
European countries with separate collection 
systems)

This symbol on the product or on its 
packaging indicates that the product 
must not be disposed of with normal 
household waste. Instead, it is your 
responsibility to dispose of your waste 

equipment by arranging to return it to a designated 
collection point for the recycling of waste electrical 
and electronic equipment. By separating and recycling 
your waste equipment at the time of disposal you will 
help to conserve natural resources and ensure that the 
equipment is recycled in a manner that protects human 
health and the environment. For more information 
about recycling this product, please contact your local 

city  office,  your  household  waste  disposal  service  or 

the shop where you have purchased the product.

Impeller  
Chamber

19. Do not force the unit back together as the 
ceramic shaft may break. If it does not reassemble 
easily check the position of the rubber end caps, 
ceramic shaft and impeller.

20.  (Aquatica  240  only)  Check  the  Prefilter 

Sponge. Rinse under tap water to remove any 
built up which may have accumulated on it. If the 
sponge shows signs of deterioration replace it. 

21. Reassemble the pump in reverse order.  We 
recommend that an aquarium safe lubricant such 
as AquaLube is used to lubricate the O-ring on the 
impeller cover.

22. Replace the filter pump in the filter chamber. 

Re-connect the duckbill.

23. Replace glass lid, lid flaps and light.

24. Ensure your hands and plugs are dry. Plug in 
the pump, light and heater. 

Содержание Aquatica 160

Страница 1: ...Inspiring Excellence in Fish Keeping Aquatica 160 240 Instruction version 4 12 2017 www aquaone com au ...

Страница 2: ...2 This page is intentionally left blank ...

Страница 3: ...wet do not unplug the appliance Disconnect the fuse or circuit breaker that supplies the power to the appliance then unplug and examine for presence of water in the socket 5 Always unplug the appliance from the electrical outlet when not in use before putting on or taking off parts before any type of maintenance or cleaning 6 Never yank the cable to pull it from the socket Pull the plug carefully ...

Страница 4: ...e product was purchased for inspection Before First Use Preparation Aqua One Spare Parts Replacement Parts Filter Media Use Aqua One Genuine Spare Parts Only See your local Aqua One Dealer and look for the number listed below for the spare part you require Alternatively you will find these numbers on the silver label located on the product Aquatica Sponge 15ppi 25174s Aquatica Sponge 35ppi 25175s ...

Страница 5: ...r Chamber 3 Media Chamber 4 Filter Intakes 5 Duckbill Outlet 6 Elbow 7 Riser Hose Know Your Filter 8 Pump 9 Heater 10 Media Basket 15ppi Sponge 11 Media Basket 35ppi Sponge 12 Media Basket Carbon 13 Media Basket Ceramic Noodles Transformer 2 1 3 4 4 5 5 6 7 8 10 11 12 13 9 ...

Страница 6: ...All equipment and accessories should only be used for the aquarium and should be purchased specifically for aquarium use Do not use any chemicals or detergents to clean anything intended for the aquarium 1 Consider where you are going to place the aquarium Keep it away from direct light or areas with large temperature fluctuations 2 Assemble cabinet according to instructions supplied with the cabi...

Страница 7: ...just under the glass brace To do this either use buckets or a garden hose secured in the aquarium See page 8 for location of glass brace 12 Treat the new water with a water conditioner such as Aqua One Water Conditioner and also use a bio supplement such as Aqua One Biostarter sold separately 13 Place lid supports onto the glass lids Place lids onto the aquarium as shown on page 8 14 Place light a...

Страница 8: ...8 1 2 3 4 Set Up Instructions 1 2 3 4 Lid Placement Light and Lid Flap Placement Glass Brace Feeder Holes ...

Страница 9: ... 1 2 3 4 5 6 1 2 3 4 5 6 7 the aquarium Remember to empty some water from the aquarium before adding anything to it REMEMBER LIVE PLANTS NEED TO BE FED An aquarium safe plant fertiliser should be used LIGHTING It is recommended that the light is turned completely off for at least 8 hours per day to allow the fish a proper night period More than 10 hours of full light daily can encourage excessive ...

Страница 10: ...enough water to replace the amount removed with Aqua One Water Conditioner Sold separately as per the instructions on the bottle Let the water sit for at least 10 minutes 8 Refill the aquarium gently with the new water 9 Turn the filter back on and ensure that water is flowing through the filter outlet 10 Turn the heater back on 11 Add a filter bio supplement such as Aqua One Bio Start 12 Replace ...

Страница 11: ...quipment Applicable in the European Union and other European countries with separate collection systems This symbol on the product or on its packaging indicates that the product must not be disposed of with normal household waste Instead it is your responsibility to dispose of your waste equipment by arranging to return it to a designated collection point for the recycling of waste electrical and ...

Страница 12: ...l liquid spillage or submersion of goods not designed to sustain such use or duress 2 3 Where inspections reveal goods are in normal working order including where noise or vibration is consistent with normal goods operation 2 4 Attempted repairs or modifications by unauthorised persons including but not limited to the drilling of holes in the aquarium glass by unauthorised persons 2 5 Where the go...

Отзывы: