Doc. 12-7852-r05 (8/5/16)
42
DIVE OPERATION
© Aqua Lung International, Inc. (2016)
CONDITIONAL VIOLATION (CV)
Upon ascent above the required Decompression (deco) Stop depth, operation will enter Conditional Violation dur-
ing which time no off gassing credit will be given. The Audible alarm will sound. Additionally, the full N2 Bar Graph,
down arrows, and DOWN TO STOP message will flash until the audible alarm is silenced, then the N2 Bar Graph
will be solid.
• The down arrows continues to flash until descending below the required Stop Depth (within stop zone), then the
full stop graphic (opposed arrows with stop bar) will be on solid.
• If you descend deeper than the required Decompression Stop before 5 minutes elapse, Decompression opera-
tion will continue with no off gassing credit given for time above the Stop. Instead, for each minute above the
Stop 1½ minutes of penalty time will be added to the required Stop Time.
• The added penalty (decompression) time will have to be worked off before obtaining off gassing credit.
• Once the penalty time is worked off, and off gassing credit begins, required Decompression Stop Depths and
Time will decrease toward zero. The N2 Bar Graph will recede into the No Decompression zone, and operation
will revert to No Decompression mode.
message and
arrows flashing
N2 Bar Graph
flashing
missed
stop
depth
stop time (min)
DELAYED VIOLATION 1 (DV 1)
If you remain shallower than a Deco Stop Depth for more than 5 minutes, operation will enter DV1* which is a
continuation of CV with penalty time still being added. Again, the audible alarm will sound and the full N2 Bar
Graph will flash until it is silenced. ALT screens are accessed and appear similar to Deco ALT screens.
*The difference is that 5 minutes after surfacing from the dive, operation will now enter Violation Gauge Mode.
• Down arrow and DOWN TO STOP message continues to flash until descending below the required Stop Depth,
then the full stop graphic will be on solid.
• If the DV1 status is ignored, the i750TC will enter DV1 Surface mode for 5 minutes upon surfacing from the dive.
Down arrows and Deco Stop depth/time will alternate with VIOLATION. After 5 minutes on the surface in DV1
mode, the unit will enter VGM (Violation Gauge Mode).
DV1 DIVE MAIN
DV1 < 5 MIN ON SURFACE
time required at
missed stop (min)
missed stop
depth
alternating with
violation
Содержание i750TC
Страница 1: ... Aqua Lung International Inc 2016 Dive Computer Owner s Manual Doc 12 7852 r05 8 5 16 i750TC ...
Страница 6: ...Doc 12 7852 r05 8 5 16 6 Aqua Lung International Inc 2016 GETTING STARTED ...
Страница 11: ...Doc 12 7852 r05 8 5 16 11 Aqua Lung International Inc 2016 HOME MENU ...
Страница 18: ...Doc 12 7852 r05 8 5 16 18 Aqua Lung International Inc 2016 DIVE FEATURES ...
Страница 25: ...Doc 12 7852 r05 8 5 16 25 Aqua Lung International Inc 2016 DIVE SURFACE MODE ...
Страница 35: ...Doc 12 7852 r05 8 5 16 35 Aqua Lung International Inc 2016 DIVE OPERATION ...
Страница 47: ...Doc 12 7852 r05 8 5 16 47 Aqua Lung International Inc 2016 GAUGE MODE ...
Страница 52: ...Doc 12 7852 r05 8 5 16 52 Aqua Lung International Inc 2016 FREE MODE ...
Страница 59: ...Doc 12 7852 r05 8 5 16 59 Aqua Lung International Inc 2016 COMPASS MODE ...
Страница 67: ...Doc 12 7852 r05 8 5 16 67 Aqua Lung International Inc 2016 REFERENCE ...
Страница 72: ...Doc 12 7852 r05 8 5 16 72 Aqua Lung International Inc 2016 TECHNICAL DATA ...
Страница 79: ...www aqualung com ...