— Page 14 —
© 2011 Aqua-Hot
®
450-D Hydronic Heating System Owner’s Manual
General Information
Should the Aqua-Hot Hydronic Heating System fail to
operate, complete the following checks:
1. Verify that the Aqua-Hot’s access cover is securely
installed. The Aqua-Hot Hydronic Heating System
will not operate if the access cover is not fully in-
stalled.
2. Ensure that the vehicle’s fuel tank contains a suffi-
cient level of fuel. The Aqua-Hot system will not oper-
ate if the fuel level is at or below 1/4 tank.
3. Ensure that the Aqua-Hot’s boiler tank has an ade-
quate supply of antifreeze and water heating solution
by checking the level at the expansion tank. If the
level is low, reference the maintenance section of
this manual for refilling instructions.
4. Check the Aqua-Hot’s electronic controller for any
RED lights indicating a fault condition.
If the Aqua-Hot Heating System’s failure to operate is not
resolved with the aforementioned checks, please contact
the Aqua-Hot Heating Systems Technical Support De-
partment at
1-800-685-4298
for additional assistance or
visit the web site at
www.aquahot.com.
If the Aqua-Hot’s diesel-burner switch “Indicator Light”
does not illuminate, and the diesel-burner is not function-
ing, locate the electronic controller and check the follow-
ing:
1. Check the Aqua-Hot’s electronic controller for any
RED lights indicating a fault condition. Reference
figure 11.
2. Check for loose wire connections on the electronic
controller’s terminal strips/plugs. When checking for
loose terminal strips/plugs, remove the electronic
controller faceplate by unscrewing the four cover
screws.
3. Remove the Aqua-Hot’s access cover and check for
loose plug connections on the diesel-burner control-
ler unit. Reference figure 2.
4. Ensure the vehicle’s fuel tank has a sufficient level of
fuel.
5. If the Aqua-Hot still fails to operate, please contact
the Aqua-Hot Heating Systems Technical Support
Department at
1-800-685-4298
or visit the web site
at
www.aquahot.com
T
ROUBLESHOOTING
Electronic Controller Diagnostic
Low Tank-Level Cutoff Indicator Light
This indicator light will illuminate RED when either the 120
Volt-AC electric heating element and/or diesel-burner have
automatically shut down due to a low antifreeze and water
heating solution level inside the Aqua-Hot’s boiler tank.
This fault will automatically reset when the low level condi-
tion is corrected.
Low Battery Voltage Fault Indicator Light
This indicator light will illuminate RED and the diesel-burner
will shut down whenever the 12 Volt-DC voltage level is too
low for the Aqua-Hot to operate properly. This fault must be
manually reset after the voltage level has been restored to
the 12-Volt-DC battery system. Reference the
Low
Voltage
information below.
Low Voltage Fault Indicator Light and Reset Button
The Aqua-Hot’s electronic controller must be manually re-
set whenever the low battery voltage fault indicator light
has been activated. The electronic controller can be reset
by turning
OFF
the diesel-burner switch on the interior
switch panel for approximately 60 seconds, then turning the
switch back
ON
by pressing the “Low Voltage Reset” but-
ton located on the electronic controller (use a thin, straight,
nonmetallic object to access the reset button through the
small hole in the faceplate).
Figure 11
NOTE:
An interlock switch prevents the Aqua-Hot from
operating when the cover is not installed and properly
in place.
Содержание 450 D
Страница 1: ...OWNERS MANUAL 2011 Aqua Hot Heating Systems Inc 450 D ...
Страница 2: ... Page 2 2011 Aqua Hot 450 D Hydronic Heating System Owner s Manual ...
Страница 22: ... Page 22 2011 Aqua Hot 450 D Hydronic Heating System Owner s Manual This area provided for notes ...
Страница 24: ...15549 East Highway 52 Fort Lupton CO 80621 800 685 4298 Fax 303 857 9000 www aquahot com LTE 907 601 ...