Maintenance Schedule
Monthly Maintenance:
Check the Aqua-Hot’s antifreeze and water heating solu-
tion to ensure that it is at the proper level. This can be
accomplished by visually checking the coolant level in the
Aqua-Hot’s Expansion Tank; reference Figure 7. Please
note that the coolant level should be checked
only
when
the Aqua-Hot is at maximum operating temperature (i.e.,
immediately after the Diesel-Burner cycles OFF). When
maximum operating temperature, the antifreeze and wa-
ter heating solution should be at the level marked “HOT”
on the Expansion Tank.
Replenishing the Antifreeze and Water Heating
Solution:
If the antifreeze and water heating solution needs replen-
ishing, remove the Expansion Tank’s cap and fill the Ex-
pansion Tank to the “HOT” level mark. When refilling,
open the Air Release Valve located on the Expansion
Tank Connection to release air pockets; reference Figure
8. Hold the valve open until all air is released. If neces-
sary, refill the Expansion Tank again. Be sure the valve is
closed when finished by hand-tightening. Reference Ap-
pendices A through C in order to determine the correct
ratio of antifreeze to water, the proper type of antifreeze,
and the water quality recommendations for the Aqua-Hot
Hydronic Heating System’s antifreeze and water heating
solution. Reference Appendix D for information about
M
AINTENANCE
the tool and usage instructions for measuring the tank’s
freeze protection level.
Annual Maintenance:
To keep the Aqua-Hot running smoothly, it is ideal to
have the Diesel-Burner tuned-up annually. A tune-up
should consist of a new Fuel Nozzle and Fuel-Filter; ref-
erence Figure 9. To ensure maximum Diesel-Burner per-
formance, always use the recommended Fuel Nozzle and
Fuel Filter when replacing these parts. Reference the
Aqua-Hot’s Service and Parts Manual for spare parts in-
formation and detailed replacement instructions, contact
the Aqua-Hot Heating Systems Technical Support De-
partment at
1-800-685-4298
for assistance or to locate
the nearest Aqua-Hot Service Center, or visit the web site
at www.aquahot.com.
DO NOT operate the Diesel-Burner and/or the Elec-
tric Heating Element without the antifreeze and water
heating solution in the Aqua-Hot’s Boiler Tank; do-
ing so will cause serious damage to the Heater.
Propylene Glycol that is “Generally Recognized As
Safe” by the FDA must be utilized for the antifreeze
and water heating solution.
NOTE:
For additional information regarding this propylene
glycol-based, boiler-type antifreeze that has been
“Generally Recognized As Safe” by the FDA, please
reference Appendix A, contact Aqua-Hot Heating Sys-
tems Technical Support Department at
1-800-685-
4298
, or visit the Web site at
www.aquahot.com
.
Figure 8
Figure 7
Fluid will reach
Expansion Tank
line when hot
Expansion
Tank Cap
Air-Release
Valve
Expansion Tank
Connection
Fuel Nozzle
Part Number:
FLX-013-150
Fuel Filter
Part Number:
FLE-120-100
Figure 9
DA N G E R !
WA R N I N G !
W
HEN
THE
A
QUA
-H
OT
IS
AT
MAXIMUM
OPERATING
TEM-
PERATURE
,
THE
COOLANT
WILL
BE
VERY
HOT! I
F
THE
A
QUA
-H
OT
’
S
HEATING
SYSTEM
IS
ACCESSED
,
SCALDING
BY
HOT
VAPOR
OR
COOLANT
COULD
RESULT
! B
EFORE
CLEAN-
ING
OR
SERVICING
,
DISCONNECT
ALL
POWER
SUPPLIES
!
Содержание 450 D
Страница 1: ...OWNERS MANUAL 2011 Aqua Hot Heating Systems Inc 450 D ...
Страница 2: ... Page 2 2011 Aqua Hot 450 D Hydronic Heating System Owner s Manual ...
Страница 22: ... Page 22 2011 Aqua Hot 450 D Hydronic Heating System Owner s Manual This area provided for notes ...
Страница 24: ...15549 East Highway 52 Fort Lupton CO 80621 800 685 4298 Fax 303 857 9000 www aquahot com LTE 907 601 ...