7
5.5 Manual-Inverter Mode
1
Hold
for more than 3 seconds to unlock the screen;
2
Press
to start. The pump will run at 80% capacity after priming.
3
The running capacity could be adjusted from 30% ~ 100% , by
pressing
or
with 5% for each step.
4
Press
to check the instant flow of the running capacity, and press
again will back to the running capacity interface.
5.6 Auto-Inverter Mode
According to the set water flow, the pump could automatically detect the system pressure to
adjust the speed of motor, to ensure a constant flow.
1
Unlock the screen, press
to shift from the Manual-Inverter mode to
Auto-Inverter mode.
2
Press
or
to set the flow rate, each step by 1m³/h.
3
Press
again to switch to Manual-Inverter mode.
5.7 Timer mode
The pump’s on/off and running capacity could be commanded by timer, which could be
programmed daily as needed.
1
Enter timer setting by pressing
2
Press
or
to set the local time
3
Press
to confirm and move to time-1 setting
4
Press
or
to choose the desired running periods and specific capacity
or flow