AQUAERO 5/6
power the PC up and down as well, usually USB keyboard commands are
used.
22. Data log (aquasuite/device menu)
22. Data log (aquasuite/device menu)
22. Data log (aquasuite/device menu)
22. Data log (aquasuite/device menu)
The aquaero 5/6 unit can be configured to record measured values over an
extended period of time. The menu “Log data” can be used to configure up
to 16 measured values to be recorded at adjustable time intervals. The
recorded information can then be displayed as charts on the aquaero display
→
itself (menu “User interface” “Information pages”) or be transmitted to the
Windows software aquasuite via USB connection.
aquasuite: Select “Data log” from the device list for the device to be config-
ured.
Device menu: Select “Data log” from the menu list and confirm by pressing
the middle side key.
22.1. Configure log data sets
22.1. Configure log data sets
22.1. Configure log data sets
22.1. Configure log data sets
Data source and time interval can be configured for each log data set. The
aquaero has a limited memory capacity for log data, approximately 100,000
data sets can be stored in total. Once the available memory is exhausted, the
aquaero will start overwriting the oldest data in memory. Up to 16 log data
sets can be configured independently.
The information pages “Diagrams” can be used to plot a chart from log data
on the aquaero device display (see information pages, aquaero 5/6 XT/PRO
only).
22.2. Transfer log data into aquasuite (aquasuite only)
22.2. Transfer log data into aquasuite (aquasuite only)
22.2. Transfer log data into aquasuite (aquasuite only)
22.2. Transfer log data into aquasuite (aquasuite only)
In order to transfer log data from the aquaero, a corresponding log has to be
configured in the global “Data log” of the aquasuite for each data set to be
transferred. Data can then be transferred by clicking “Synchronize log data
with aquasuite” the “Data log” window of the corresponding aquaero in the
device listing of the aquasuite. During the synchronization process, data will
be transferred from the aquaero memory into the aquasuite data base adher-
ing to the log interval configured in the aquasuite. If data is logged with a ten
second time interval in the aquaero for example, a one minute time interval
setting in the aquasuite will result in every sixth aquaero data set being saved
in the aquasuite data base.