AQUADUCT
the aquaduct. After filling the aquaduct and after changes at the cooling
system a calibration of this measuring is necessary. After that the fill level
is measured at every start of the aquaduct and is shown on the display
as well as in the software.
To ensure a reliable fill level detection, the reference value must be de-
termined first! Due to the principle of measurement, the reference value
must be reset after any change to the water cooling circuit, for example
after integrating an additional water block to the system.
Calibration of the fill level detection:
1. Check the fill level of the aquaduct using the mechanical indicator
in the right side profile and add coolant until the black ball is ap-
proximately 1 cm below the upper rim if necessary.
2. Activate the calibration using the PC Software.
During calibration, the pump frequency is temporarily set to a (low) ref-
erence value. After completion, the originally set frequency ist restored.
13. Maintenance and care instructions
13. Maintenance and care instructions
13. Maintenance and care instructions
13. Maintenance and care instructions
Regularly check the system on possible leaks and observe the water
level. If you use the coolant we specified, it is sufficient to exchange it
once a year. Since our sets are exclusively closed cooling circuits, an in-
trusion of air oxygen is not to be expected. This is why the possibility of a
biological pollution is very small.
You can check the condition of the coolant through the Plexiglas lids of
the coolers and in the profiles of the aquaduct. If there is any pollution
you should exchange the cooling medium.
In operation, the pump is maintenance free. All the gaskets in the system
have to be exchanged if they are visibly worn out, after 5 years at the
latest. You can get spare gaskets from us or let us do the exchange.
Also check the hoses for changes in material regularly. Should they get
brittle or have scratches you should exchange them.