W E L C O M E
Congratulations on the purchase of your new Auto-Chlor Chlorine Generator. Your purchase will minimize the
efforts needed to maintain your pool and maximize your enjoyment for many years. Before installation or
operation, please read these instructions carefully. This manual contains easy to follow step-by-step
procedures to properly install and operate your system. A little time spent understanding your system and its
parts will assure successful, trouble-free installation and usage. When working around your pool, please take
care to avoid hazards such as electrical wires and chemicals. CAUTION! Safety comes first!
WARNING SAFETY FIRST
READ AND FOLLOW ALL INSTRUCTIONS
All electrical work must be performed by a licensed electrician and conform to all national, state, and local
codes. When installing and using this electrical equipment, basic safety precautions should always be
followed, including the following:
•
DO NOT OPEN THE GENERATOR BOX – NOT A SERVICABLE UNIT
•
Disconnect all AC power before
installation.
•
WARNING – To reduce the risk of injury, do not permit children to use this product.
•
The Control Box must be mounted vertically on a flat surface and a minimum of 5 ft (1.5m) horizontal
distance (or more, if local codes require) from the pool/spa.
•
In Canada and some other regions, local codes require the unit be connected only to a circuit that is
protected by a ground-fault circuit-interrupter (GFCI). The installer should provide this GFCI
requirement. The GFCI should be tested on a regular basis by pushing the test button. If the GFCI
fails to operate correctly, there is ground current flowing indicating the possibility of an electric shock.
Do not use this unit. Disconnect unit and have a qualified professional correct the problem before
using.
•
The power cable must be hardwired to the time clock so that the system cannot operate without the
pump.
•
A build-up of flammable fumes can result in a hazardous condition if the Cell is allowed to operate
without flow. This machine must be operated only with an approved in-line flow sensor.
•
The Flow Sensor must be installed between the last piece of apparatus and the Cell,
upstream of the cell
•
ALWAYS ADD ACID TO WATER, NEVER WATER TO ACID.
•
SAVE THESE INSTRUCTIONS.
3