Figure 128
#ONNECTIONS$IMENSIONSAND%NGINEERINGDATA
ALLDIMENSIONSININCHES
Part number 550-100-305/0916
98
AquaBalance
TM
W
ALL
M
OUNT
GAS
-
FIRED
WATER
BOILER
— C
OMBI
Boiler Manual
35
Connections,
Dimensions and Engineering data
Figure 129
%NGINEERINGDATA
Boiler
Model
3HIPPING
weight
/PERATING
weight
Water
content
6ENTAIRPIPESIZE
0ROVIDEA
SEPARATEVENTFOREACH
BOILER
%LECTRICAL
service
required
0OUNDS
PERBOILER
0OUNDS
PERBOILER
'ALLONS
PERBOILER
!MPS
PERBOILER
.OTE
.OTE
.OTE
WMB-155C
87
93
0.75
3”
15.0
.OTES
1
Total amp requirement includes up to one circulator, Low Water Cutoff, 3-Way Valve not to exceed 3.0 amps total.
2
Operating weight is the total weight of the boiler, including water.
3
Boiler venting is 3” only.
All of the boilers will automatically de-rate as vent/air pipe length increases, due to the pressure loss through the piping.
See Figure 131, page 99 for details.
All installations require a separate vent pipe and termination for each boiler.
6ENTPIPINGCANNOTBEMANIFOLDED
. Install
and terminate vents as described in vent/air installation instructions in this manual.
Combustion air piping can be individually piped. See venting section in this manual.