31
www.getaqila.com
Connecting wired Sensor &
Electrical Facilities
Interface Cable 1
Interface Cable 2
Grounding
General Port
Normal Open (NO)
Normal Closed (NC)
Power Output for wired sensors/
accessories
Grounding
Wired Sensors/ Accessories:
It supports 2 groups of wired sensor/accessories.
Please choose the wired sensor type after connected.
Connect the Wired Siren
Connect the negative pole to the GND block, and the positive pole to the
N.O block.
Connection to Electrical Facilities Using AC Current:
Enable to turn on electronic facilities such as lights, or fences to quickly
deter intruders when they occur alarm.
Note! Wired accessories require a DC 12V power and cannot be used
only with batteries.
Connect Wired Sensors to Wired Zone 1
Connect N.C. type door sensor to the wired zone. One cable for IN1 or
IN2 block, others for GND block.
Send SMS 74 to choose the wired sensor type to be N.C. Test if the alarm
occur when the wired sensor is triggered.