Shaker type dust collector
15
14.3 Control panel
The control panel is designed to start the fan and shaker system. It allows the start of an
automatic shaker sequence every time the unit is shut down. It is possible to set the duration
of the shaker time and the delay between the shutdown of the fan and the start of the shaker
sequence.
14.4 Programming instructions
The shaker settings are adjusted at the factory. To modify the settings, turn timer knob T1 to the
desired setting. To modify the duration of shaking mechanism, turn timer knob T2 to the desired
setting. Values shown on knobs are in seconds.
15 EXPLOSION VENT
A. Q. C., Inc. will not be held liable for injury or damages caused by a fire, a blast or an explosion
as per the agreement made upon the construction of the collector.
However, the collector is built as per NFPA-68 standards concerning explosion venting systems.
The total surface of the venting system is calculated using this norm. The explosion vent is held
shut using special handles specially designed to pop open if a sufficient pressure is applied. The
handles are adjusted at the factory following the requirements of the manufacturer, the surface
of the explosion vent and attachment method.
WARNING!
The explosion vent must face toward an area away from
workers, offices, pedestrian walkways or any other area
which may be accessible to persons, close to vegetation or
any other substance that may be damaged in the event of an
explosion.