background image

Industrial Exhaust Blower

5

  4.1  Amperage draw

Models

Voltage

Amperage

Models

Voltage

Amperage

DF-01

115-1-60

12

DF-03

115-1-60

N/A

230-1-60

6.5

230-1-60

17

208-3-60

3.1

208-3-60

9.6

460-3-60

1.6

460-3-60

4.8

575-3-60

1.4

575-3-60

3.9

DF-02

115-1-60

24

DF-05

115-1-60

N/A

230-1-60

12

230-1-60

28

208-3-60

6.8

208-3-60

15.2

460-3-60

3.4

460-3-60

7.6

575-3-60

2.7

575-3-60

6.1

  5  FAN DIMENSIONS

Voltage / HP

1 HP (6’’)

2 HP (8”)

3 HP (10’’)

5 HP (12’’)

1 phase 115/208-230

MS-DF-01A-112

MS-DF-02A-112

MS-DF-03A-112

N/A

1 phase 115/208-230

MS-DF-01A-324

MS-DF-02A-324

MS-DF-03A-324

MS-DF-05A-324

1 phase 115/208-230

MS-DF-01A-35

MS-DF-02A-35

MS-DF-03A-35

MS-DF-05A-35

Figure 2 

  A  

  B  

  F  

d4  

  E  

  G  

  C  

  H  

  h  

d1  

d3

d2  

INLET FLANGE

MODEL POWER

DIMENSIONS (IN)

WEIGHT       

(LB)

A

B

C

D

E

F

G

H

h

d1

d2

d3

d4

Nb

DF-02

2 HP

22.70 24.75 9.50 7.88 9.20 11.00 6.30 24.80 7.80 8.19 9.69 0.38 7.88

8

83

- Roof support bracket (weight: 14 lb)

03-15-2013

DRAWN BY:

DATE:

MS-DF-

1

02

SCALE:

DRAWING NO:

1:16

FAN MAXDRIVE - DF-

1

02

SPECIFICATIONS:

STATIC PRESSURE vs AIR VOLUME

OPTIONS

- Maxidrive fan DF-02

- Motor: 2hp; 3,600 rpm

- Available voltages:

1PH/115/208-230

       3PH/208-230/460/575

- Aluminium backward inclined impeller with

steel housing for spark-proof design

- Adjustable orientation air discharge

- Inlet wide mesh protective screen

- Heavy duty powder coat painted housing

- Soud level: 87 dB

  A  

  B  

  F  

d4  

  E  

  G  

  C  

  H  

  h  

d1  

d3

d2  

INLET FLANGE

MODEL POWER

DIMENSIONS (IN)

WEIGHT       

(LB)

A

B

C

D

E

F

G

H

h

d1

d2

d3

d4

Nb

DF-02

2 HP

22.70 24.75 9.50 7.88 9.20 11.00 6.30 24.80 7.80 8.19 9.69 0.38 7.88

8

83

- Roof support bracket (weight: 14 lb)

03-15-2013

DRAWN BY:

DATE:

MS-DF-

1

02

SCALE:

DRAWING NO:

1:16

FAN MAXDRIVE - DF-

1

02

SPECIFICATIONS:

STATIC PRESSURE vs AIR VOLUME

OPTIONS

- Maxidrive fan DF-02

- Motor: 2hp; 3,600 rpm

- Available voltages:

1PH/115/208-230

       3PH/208-230/460/575

- Aluminium backward inclined impeller with

steel housing for spark-proof design

- Adjustable orientation air discharge

- Inlet wide mesh protective screen

- Heavy duty powder coat painted housing

- Soud level: 87 dB

  A  

  B  

  F  

d4  

  E  

  G  

  C  

  H  

  h  

d1  

d3

d2  

INLET FLANGE

MODEL POWER

DIMENSIONS (IN)

WEIGHT       

(LB)

A

B

C

D

E

F

G

H

h

d1

d2

d3

d4

Nb

DF-02

2 HP

22.70 24.75 9.50 7.88 9.20 11.00 6.30 24.80 7.80 8.19 9.69 0.38 7.88

8

83

- Roof support bracket (weight: 14 lb)

03-15-2013

DRAWN BY:

DATE:

MS-DF-

1

02

SCALE:

DRAWING NO:

1:16

FAN MAXDRIVE - DF-

1

02

SPECIFICATIONS:

STATIC PRESSURE vs AIR VOLUME

OPTIONS

- Maxidrive fan DF-02

- Motor: 2hp; 3,600 rpm

- Available voltages:

1PH/115/208-230

       3PH/208-230/460/575

- Aluminium backward inclined impeller with

steel housing for spark-proof design

- Adjustable orientation air discharge

- Inlet wide mesh protective screen

- Heavy duty powder coat painted housing

- Soud level: 87 dB

  A  

  B  

  F  

d4  

  E  

  G  

  C  

  H  

  h  

d1  

d3

d2  

INLET FLANGE

MODEL POWER

DIMENSIONS (IN)

WEIGHT       

(LB)

A

B

C

D

E

F

G

H

h

d1

d2

d3

d4

Nb

DF-02

2 HP

22.70 24.75 9.50 7.88 9.20 11.00 6.30 24.80 7.80 8.19 9.69 0.38 7.88

8

83

- Roof support bracket (weight: 14 lb)

03-15-2013

DRAWN BY:

DATE:

MS-DF-

1

02

SCALE:

DRAWING NO:

1:16

FAN MAXDRIVE - DF-

1

02

SPECIFICATIONS:

STATIC PRESSURE vs AIR VOLUME

OPTIONS

- Maxidrive fan DF-02

- Motor: 2hp; 3,600 rpm

- Available voltages:

1PH/115/208-230

       3PH/208-230/460/575

- Aluminium backward inclined impeller with

steel housing for spark-proof design

- Adjustable orientation air discharge

- Inlet wide mesh protective screen

- Heavy duty powder coat painted housing

- Soud level: 87 dB

INLET FLANGE

Содержание MAXIDRIVE MS-DF-01A-112

Страница 1: ...tion use and maintenance This manual is property of the owner Leave with the unit when set up and start up are complete AQC Dust Collecting Systems inc reserves the right to change design and specific...

Страница 2: ...ormal usage 6 7 Operation and purpose 6 8 Components 6 9 Installation 7 9 1 Inspection of goods 7 9 2 Location 7 9 3 Installation of MAXIDRIVE fan with MAXAIR fume arm 7 9 4 Installation of MAXIDRIVE...

Страница 3: ...onnel using the system will have to trained on safety measures and maintenance instructions 2 INFORMATION ON THE MAXIDRIVE BACKWARD INCLINED DIRECT DRIVE BLOWER Model Serial number Delivery date Date...

Страница 4: ...hose reels MAXIDROP hose drop systems etc 3 1 Each Maxidrive fan includes 11 and 14 gauge powder coat painted steel housing Spark proof aluminum backward inclined impeller optional steel impeller Inl...

Страница 5: ...8 19 9 69 0 38 7 88 8 83 Roof support bracket weight 14 lb SPECIFICATIONS STATIC PRESSURE vs AIR VOLUME OPTIONS Maxidrive fan DF 02 Motor 2hp 3 600 rpm Available voltages 1PH 115 208 230 3PH 208 230...

Страница 6: ...motors are recommended when fan is installed in reactive gas environments 8 COMPONENTS 1 Housing 2 Impeller 3 Motor 4 Inlet cone 5 Companion flange straight pipe or bolted 6 Motor support plate 7 Mot...

Страница 7: ...rance when receiving the goods Report damages to carrier immediately Failure to do so will void future claims 9 2 Location 1 The area where the blower will be installed should be able to sustain the w...

Страница 8: ...stallation of MAXIDRIVE fan with MAXIREEL exhaust hose reel Note AQC usually supplies fan and reel factory assembled If fan is shipped separate bolt fan flanged inlet to hose reel flanged outlet Ensur...

Страница 9: ...noises Check for vibration Monthly Cooling impeller Ensure cooling impeller is not jammed Yearly All components Perform amperage draw reading Remove air inlet connection and check status of impeller...

Страница 10: ...fan is vibrating Unbalanced fan impeller Worn or damaged bearings Balance the fan to Amca class G 6 3 or re place with a new one Replace the bearings Check for obstruction Loose bolts on motor plate o...

Страница 11: ...nty customer must notify Seller in writing of the Product defect which notice shall include a reasonable description of the defect within 10 days from the date such defect is discovered or ought to ha...

Страница 12: ...ossibility of such damages or could have reasonably foreseen them 14 3 Fire and Explosion and Acceptance of Risk Customer acknowledges that improper installation or use of the Product may result in fi...

Отзывы: