Display (HH:MM) & (MM:SS):
Any time the displayed time is >60 minutes, the display will show
HH:MM, with the colons flashing to indicate time is
incrementing/
will
visually confirm the timer is active.
decrementing. If the displayed time is < 60 minute,
the display will show MM:SS. The seconds decrementing
Cycle LED’s:
The zone and bun warmer LED’s will cycle with the element. The
ZONE LED’s are ON when that mode is active.
5:15
150
HEAT
HEAT
HOLD
HOLD
1
2
ZONE 2
ZONE 1
LED’s cycle with element
LED’s ON
Hot Dog LED Cycling
SERVICE
ALARMS
Refer to the following display and alarm code table. Once the problem is resolved the alarm code turns off.
Alarms are zone specific where applicable so operation can continue, for example, on Zone 2 should Zone
1 have a probe alarm. For AL06, Bun RTD, since it does not have a dedicated display, instead the BUN LED
Alarm Display Example
HEAT
HEAT
HOLD
HOLD
1
2
will flash, and a press on the ‘BUN’ key
will then show ‘AL06’ for 3 seconds on
the lower display, then return.
Code Description Display
Alarm Codes
01
Invalid capability control setting
AL01
02
Key shorted (press>30 seconds)
AL02
03
Inlet probe error (open or shorted)
AL03
04
Outlet probe error (open or shorted)
Al04
05
Possible corrupted EEPROM
AL05
06
Bun RTD error
AL06
User Range:
The control will be supplied with the factory default settings and range shown. If needed, the range can be
narrowed or widened up to the maximum range shown on the FACTORY DEFAULTS table.
Factory Defaults:
The control will be supplied with the factory default settings and range shown.
COOK Temp
HOLD Temp
COOK Time
HOLD Time
BUN Temp
BUN Time
190°F (88°C)
150°F (66°C)
30 minutes
60 minutes
110°F
No limit
140° to 230°F (60° to 110°C)
140° to 190°F (60° to 88°C)
0* to 120 minutes (COOK bypassed if ‘0’)
1 to 240 minutes/unlimited 1 (stops @ 99hrs)
90° to 150°F
N/A
140° to 250°F (60° to 120°C)
140° to 210 F (60° to 100°C)
N/A
N/A
90° to 150°F
N/A
Hot Dog
Factory User Range
(Max range available)
Item Factory Setting Default User Range
Temp
180°F
140° to 450°F
90° to 500°F
Temp Offset
0°F (0°C)
0° to -20°F (0° to 10°C)
N/A
Shelf Warmer
Factory User Range
(Max range available)
Item Factory Setting Default User Range
11