background image

LIGHTING INSTRUCTIONS 

 
HDMG Griddles are furnished with either a pilot safety valve or a standing pilot (not available in the European 
Community). Please follow the instructions for your unit. HMG Griddles are furnished with either a flame failure 
pilot or a standing pilot (not available in the European community). 

Pilot Operation HMG Flame Failure Gas Valve:  

Operation on the gas valve pilot.

 

1.  Turn knob on the main gas valve to the pilot position.  

2.  Depress knob to start gas flow to the pilot valve.  

3.  Light pilot valve. 

a.  Using a match or taper 

4.  Hold in knob for 15 to 30 seconds to heat up the thermocouple. 

5.  Release knob and turn to the desired gas flow position. 

a.  If pilot goes out repeat steps 1-4, some thermocouples will take longer to heat up 

Standing Pilot Lighting Instructions: 

(Not Available in the European Community) 

The pilot lights on the broilers have been set at the factory. A screwdriver may be required for the first lighting to 
adjust the flame for your elevation. 

1.  Turn off the manual shut off valve and wait 5 minutes to clear the gas. 

2.  Turn all knobs to the "OFF" position. 

3.  The valve can be accessed through an opening in the front panel or remove the cooking grates and light 

the pilot from above. 

4.  Turn the manual shut off valve on. 

5.  Hold an ignition source (match) to both openings on the pilot tube. When the flames are established, 

remove the ignition source. 

6.  Turn the burner knobs to "HI". If the burner does not ignite, promptly open the pilot valve more. If the pilot 

flame appears larger than necessary, turn it down and reset burner ignition. The pilot flame should be as 
small as possible but large enough to guarantee reliable ignition of the burners when the knobs are turned 
to "HI". 

RELIGHTING PILOT 

If the pilot light should go out for any reason: 

 

Promptly shut off all gas at the manual shut off valve. 

 

Turn off all knobs and pilot valves; wait 5 minutes to clear gas. 

 

Relight following steps 4 through 6 under Standing Pilot Lighting Instructions. 

HDTG LIGHTING THE MAIN BURNER: 

Since the burner is lit from constantly burning pilot, turn knobs to "HI" to put the unit in operation; then adjust to 
any desired position between "LO" and "HI". 

 

  To light burner, turn knob to "max." then back off to the desired flame level. The range of adjustment is 

virtually infinite between high and off. (At the small flame, there is a pre-set low). 

  When the broiler is first heated, it will smoke until oil used in manufacturing, preservation and dust from 

storage and shipping are burned off. An hour at "max." on all burners is usually sufficient. 

 

Turn knobs off and let cool 

Содержание HMG-2424i

Страница 1: ...and liquids in the vicinity of this or any other appliance WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation o...

Страница 2: ...d liquids in the vicinity of this or any other appliance Keep the area free and clear of combustibles See ANZI Z83 14B 1991 NOTICE Instructions to be followed if anyone smells gas should be posted in...

Страница 3: ...n is fully trained and is aware of all precautions Accidents problems can result by a failure to follow fundamental rules and precautions The following words and symbols found in this manual alert you...

Страница 4: ...Do not slide unit with legs mounted lift if necessary to move unit Pipe threading compound must be resistant to the action of liquefied petroleum gases Caution DO NOT use an open flame to check for l...

Страница 5: ...15 437 392 1 4 32 000 9 78 128 000 37 5 5 12 4 HMG 2460i 59 844 1520 0 24 609 6 15 437 392 1 5 32 000 9 78 160 000 46 9 5 12 4 HMG 2472i 71 844 1824 8 24 609 6 15 437 392 1 6 32 000 9 78 192 000 56 3...

Страница 6: ...With the front panel removed remove the plug from the manifold Place a fitting in the plug opening and connect a manometer For Natural gas the pressure in the manifold should be 5 water column or 12 4...

Страница 7: ...7 which may accumulate around this cap The openings must remain open for the regulator to function Clean more often in a very greasy atmosphere...

Страница 8: ...rates and light the pilot from above 4 Turn the manual shut off valve on 5 Hold an ignition source match to both openings on the pilot tube When the flames are established remove the ignition source 6...

Страница 9: ...act as the heart of the ventilating system for the room or area in which the unit is installed and will leave the unit independent of changing draft conditions All valves must be checked and lubricate...

Страница 10: ...ved After removal of the detergent the surface of the plate should then be covered with a thin film of oil to prevent rusting Clean stainless surfaces with a damp cloth and polish with a soft dry clot...

Страница 11: ...ing into steam Food sticks to griddle Heat is set too high Griddle surface needs cleaning and or seasoning Surface under food may not have been covered with enough cooking oil Food burned around edges...

Страница 12: ...94 Weldm t Griddle Plate 1 22241614 Weldm t Griddle Plate 1 22241734 Weldm t Griddle Plate 1 2 21826433 Side Firebox 2 2 2 2 2 3 21826022 Body 24 Firebox 1 21826122 Body 36 Firebox 1 21826222 Body 48...

Страница 13: ...652 Panel Back 36 1 21826252 Panel Back 48 1 21826332 Panel Back 60 1 21826452 Panel Back 72 1 20 22241253 Panel Control 24 1 22241373 Panel Control 36 1 22241493 Panel Control 48 1 22241613 Panel Con...

Страница 14: ...2 3 21826036 Body 24 Firebox 1 21826136 Body 36 Firebox 1 21826236 Body 48 Firebox 1 21826336 Body 60 Firebox 1 21826436 Body 72 Firebox 1 4 21826017 Support Bumer 2 21826117 Support Bumer 2 21826217...

Страница 15: ...D Shaft 2 3 4 5 6 25 8633700 Leg 2 Dia Hvy Dty 4 4 4 4 4 26 2065839 Adapter 15 Angle Elbow 2 3 4 5 6 27 22400003 Brace Leg 2 2 2 2 2 28 21826134 Channel Stiffiner NA 1 21826234 Channel Stiffiner 1 21...

Страница 16: ...16 NOTES...

Страница 17: ...17 NOTES...

Страница 18: ...e conclusion of this warranty period portable units must be taken to or sent prepaid to the APW Wyott Authorized Service Agency for in warranty repairs No mileage or travel charges are allowed on port...

Отзывы: