WARNING:

 Keep the appliance free & clear of all combustible substances. If gas odor is 

detected at any time, immediately shut unit down at the main shutoff valve. Do not permit 
any open flames in the area of the appliance. Immediately contact an authorized Service 
Agency or your local Gas Supplier for service. 

 

 

 

WARNING:

 Do not obstruct either the air inlet (underneath unit) or the ventilation air 

(back of unit). Provisions must be provided to provide an adequate air supply to the 
griddle. 

 

 

 

NOTICE:

 Local codes regarding installation vary greatly from one area to another. The 

National Fire Protection Association, Inc., states in its NFPA96 latest edition that local 
codes are "Authority Having Jurisdiction" when it comes to requirement for installation of 
equipment. Therefore, installation should comply with all local codes.

 

 

 
 

GENERAL INSTALLATION INSTRUCTIONS 

Ensure gas supply and gas type, as shown on unit nameplate, agree. 

Unit installation must conform to the National Fuel Gas Code, ANSI Z223.1/NFPA 54, the National Gas 
Installation Code, CSA-B149.1, or the Propane Installation Code, CSA-B149.2 as applicable and in accordance 
with local codes. 

Screw legs into the permanently fastened nuts on the four corners of the unit and tighten by hand. Level the 
unit by turning the adjustment screw at the bottom of each leg. Do not slide unit with legs mounted, lift if 
necessary to move unit.  

Pipe threading compound must be resistant to the action of liquefied petroleum gases.  

Caution:

 DO NOT use an open flame to check for leaks. Check all gas piping for leaks with a soap and water 

solution before operating unit. 

THESE UNITS ARE SUITABLE FOR INSTALLATION ON NON-COMBUSTIBLE SURFACES ONLY. 

Noncombustible clearances: 

0" sides (0 mm)               0" rear (0 mm)               4" floor (102mm) 

Do not obstruct the flow of combustion and ventilation air, under the unit by the legs or behind the unit by the 
flue.  

Adequate clearance for air openings into the combustion chamber is required. Do not place objects between 
the bottom of the unit and the counter top.  

There must be adequate clearance for removal of the front panel. All major parts except the burners are 
removable thru the front if the gas line is disconnected. 

Unit must have adequate clearances for servicing. (Sides = 0", Rear = 0", Floor = 4"). 

European Community Installation Instructions: 

"THIS APPLIANCE MUST BE FITTED BY A COMPETENT PERSON. IN THE UK, CORGI REGISTERED 
INSTALLERS (INCLUDING THE REGIONS OF BRITISH GAS) UNDERTAKE TO WORK TO SAFE AND 
SATISFACTORY STANDARDS. THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE 
GAS SAFETY (INSTALLATION AND USE) REGULATIONS AND THE RELEVANT BUILDING REGULATIONS 
/ IEE. REGULATIONS. DETAILED RECOMMENDATIONS ARE CONTAINED IN THE FOLLOWING BRITISH 
STANDARD CODES OF PRACTICE - BS 6172, BS 5440 PART 2, BS 6891" 

"THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE RULES IN FORCE"  

Содержание HMG-2424i

Страница 1: ...and liquids in the vicinity of this or any other appliance WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation o...

Страница 2: ...d liquids in the vicinity of this or any other appliance Keep the area free and clear of combustibles See ANZI Z83 14B 1991 NOTICE Instructions to be followed if anyone smells gas should be posted in...

Страница 3: ...n is fully trained and is aware of all precautions Accidents problems can result by a failure to follow fundamental rules and precautions The following words and symbols found in this manual alert you...

Страница 4: ...Do not slide unit with legs mounted lift if necessary to move unit Pipe threading compound must be resistant to the action of liquefied petroleum gases Caution DO NOT use an open flame to check for l...

Страница 5: ...15 437 392 1 4 32 000 9 78 128 000 37 5 5 12 4 HMG 2460i 59 844 1520 0 24 609 6 15 437 392 1 5 32 000 9 78 160 000 46 9 5 12 4 HMG 2472i 71 844 1824 8 24 609 6 15 437 392 1 6 32 000 9 78 192 000 56 3...

Страница 6: ...With the front panel removed remove the plug from the manifold Place a fitting in the plug opening and connect a manometer For Natural gas the pressure in the manifold should be 5 water column or 12 4...

Страница 7: ...7 which may accumulate around this cap The openings must remain open for the regulator to function Clean more often in a very greasy atmosphere...

Страница 8: ...rates and light the pilot from above 4 Turn the manual shut off valve on 5 Hold an ignition source match to both openings on the pilot tube When the flames are established remove the ignition source 6...

Страница 9: ...act as the heart of the ventilating system for the room or area in which the unit is installed and will leave the unit independent of changing draft conditions All valves must be checked and lubricate...

Страница 10: ...ved After removal of the detergent the surface of the plate should then be covered with a thin film of oil to prevent rusting Clean stainless surfaces with a damp cloth and polish with a soft dry clot...

Страница 11: ...ing into steam Food sticks to griddle Heat is set too high Griddle surface needs cleaning and or seasoning Surface under food may not have been covered with enough cooking oil Food burned around edges...

Страница 12: ...94 Weldm t Griddle Plate 1 22241614 Weldm t Griddle Plate 1 22241734 Weldm t Griddle Plate 1 2 21826433 Side Firebox 2 2 2 2 2 3 21826022 Body 24 Firebox 1 21826122 Body 36 Firebox 1 21826222 Body 48...

Страница 13: ...652 Panel Back 36 1 21826252 Panel Back 48 1 21826332 Panel Back 60 1 21826452 Panel Back 72 1 20 22241253 Panel Control 24 1 22241373 Panel Control 36 1 22241493 Panel Control 48 1 22241613 Panel Con...

Страница 14: ...2 3 21826036 Body 24 Firebox 1 21826136 Body 36 Firebox 1 21826236 Body 48 Firebox 1 21826336 Body 60 Firebox 1 21826436 Body 72 Firebox 1 4 21826017 Support Bumer 2 21826117 Support Bumer 2 21826217...

Страница 15: ...D Shaft 2 3 4 5 6 25 8633700 Leg 2 Dia Hvy Dty 4 4 4 4 4 26 2065839 Adapter 15 Angle Elbow 2 3 4 5 6 27 22400003 Brace Leg 2 2 2 2 2 28 21826134 Channel Stiffiner NA 1 21826234 Channel Stiffiner 1 21...

Страница 16: ...16 NOTES...

Страница 17: ...17 NOTES...

Страница 18: ...e conclusion of this warranty period portable units must be taken to or sent prepaid to the APW Wyott Authorized Service Agency for in warranty repairs No mileage or travel charges are allowed on port...

Отзывы: