4.  LIGHTING INSTRUCTIONS

HHP and HHPS Gas Open Burner Ranges are furnished with either a pilot safety valve or a standing pilot
(not available in the European Community). Please follow the instructions for your unit.

Operation of the gas valve pilot:
1.

Turn knob on the main gas valve to the pilot position

2.

Depress knob to start gas flow to the pilot valve

3.

Light pilot valve

a. Using a match or taper

4.

Hold in knob for 15 to 30 seconds to heat up the thermocouple

5.

Release knob and turn to the desired gas flow position

a. If pilot goes out repeat steps 1-4, some thermocouples will take longer to heat up

( Not Available in the European Community )

The pilot lights on the broilers have been set at the factory. A screwdriver may be required for the first lighting
to adjust the flame for your elevation.
1.

Turn off the manual shut off valve and wait 5 minutes to clear the gas.

2.

Turn all knobs to the "OFF" position.

3.

The valve can be accessed through an opening in the front panel or remove the cooking grates and
light the pilot from above.

4.

Turn the manual shut off valve on.

5.

Hold an ignition source (match) to both openings on the pilot tube. When the flames are established,
remove the ignition source.

6.

Turn the burner knobs to

“ ”

. If the burner does not ignite, promptly open the pilot valve more. If the

pilot flame appears larger than necessary, turn it down and reset burner ignition. The pilot flame should
be as small as possible but large enough to guarantee reliable ignition of the burners when the knobs
are turned to

.

If the pilot light should go out for any reason:

Promptly shut off all gas at the manual shut off valve.

Turn off all knobs and pilot valves; wait 5 minutes to clear gas.

Relight following steps 4 through 6 under

Since the burner is lit from constantly burning pilot, turn knobs to "HI" to put the unit in operation; then adjust
to any desired position between "LO" and "HI".

To light burner, turn knob to "max." then back off to the desired flame level. The range of adjustment is

virtually infinite between high and off. (At the small flame, there is a pre-set low).

When the broiler is first heated, it will smoke until oil used in manufacturing, preservation and dust from

storage and shipping are burned off. An hour at "max." on all burners is usually sufficient.

Turn knobs off and let cool

For first cooking, set the grates at maximum tilt position and preheat before broiling. You will have to

experiment with knob settings and grate position for each particular item.

Keep the grease/water pan with sufficient water to cover the entire bottom.

Clean regularly. Grates may be removed for washing in the sink. Brush out carbonized particles.

Thoroughly wash the grease/water pan.

Never attempt to move a grill section while cooking. An unexpected flare could cause severe injury. Turn off
the unit, let it cool and use potholders and/or gloves to reposition or remove. The space between the legs at
the bottom admits combustion air. DO NOT BLOCK THIS SPACE.

Pilot Operation Flame Failure Gas Valve:

Standing Pilot Lighting Instructions:

Standing Pilot Lighting Instructions.

LIGHTING THE MAIN BURNER:

CAUTION

HI

HI

RELIGHTING PILOT

l

l

l

l

l

l

l

l

l

Содержание HHP-212

Страница 1: ...eration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment WARNING I...

Страница 2: ...all contents and packaging material Installation and start up should be performed by a qualified installer who thoroughly read understands and follows these instruction If you have questions concernin...

Страница 3: ...efore installing or servicing this equipment NOTICE This symbol refers to information that needs special attention or must be fully understood even though not dangerous WARNING For your safety do not...

Страница 4: ...he design and quality of our products When used as intended and with proper care and maintenance you will experience years of reliable operation from this equipment To ensure best results it is import...

Страница 5: ...5 SPECIFICATIONS HEAVY DUTY OPEN BURNER RANGE HHP 212 21827000 SPECIFICATIONS HEAVY DUTY OPEN BURNER RANGE HHP 424 21827100...

Страница 6: ...6 SPECIFICATIONS HEAVY DUTY OPEN BURNER RANGE HHP 636 21827200 SPECIFICATIONS HEAVY DUTY OPEN BURNER RANGE HHP 848 21827300...

Страница 7: ...ignition of the burners when the knobs are turned to If the pilot light should go out for any reason Promptly shut off all gas at the manual shut off valve Turn off all knobs and pilot valves wait 5 m...

Страница 8: ...m or area in which the unit is installed and will leave the unit independent of changing draft conditions All valves must be checked and lubricated periodically This must be done by an authorized serv...

Страница 9: ...w off any dust or grease which may accumulate around this cap The openings must remain open for the regulator to function Clean more often in a very greasy atmosphere WARNING NEVER 9 NAT LP 6 CONVERSI...

Страница 10: ...10 NOTES...

Страница 11: ...11 7 REPLACEMENT PARTS LISTS EXPLODED VIEWS EXPLODED VIEW HHP...

Страница 12: ...15 PANEL CONTROL HHP 636 1 21827715 PANEL CONTROL HHP 848 1 22 21833134 BACK PANEL HDOB 212 1 21833234 BACK PANEL HDOB 424 1 21833534 BACK PANEL HDOB 636 1 21833732 BACK PANEL HDOB 848 1 23 21825031 B...

Страница 13: ...13 EXPLODED VIEW HHPS CE VERSION EXPLODED VIEW HHPS...

Страница 14: ...2 1 21827128 PANEL STOP 24 1 21827228 PANEL STOP 36 1 21827728 PANEL STOP 48 1 23 2201615 GRATE HVY DUTY HDOB 2 4 6 8 VENTURI FRONT HVY DUTY CE PANEL CONTROL HHP 212 CE PANEL CONTROL HHP 424 CE PANEL...

Страница 15: ...15 NOTES...

Страница 16: ...izedServiceAgency itwillbeservicedon siteorreplaced From day two through the conclusion of this warranty period portable units must be taken to or sent prepaid to the APW Wyott Authorized ServiceAgenc...

Страница 17: ...www apwwyott com Dallas Plant 729 Third Ave Dallas TX 75226 Local 1 214 421 7366 Toll Free 1 800 527 2100 Parts Service Fax 1 214 565 0976 Cheyenne Plant 1938 Wyott Drive Cheyenne WY 82007 Local 1 307...

Отзывы: