4
SPECIFICATIONS
ELECTRICAL
CW-13
120
60
1
4
1/5 HP
5.0 oz. - R134A
MODEL VOLTS
Hz
PHASE
AMPS
COMPRESSOR
CHARGE
DIMENSIONS
CW-13
12-1/4 (311.2) x 17-3/4 (450.9) x 27-1/16 (687.4)
11-1/2 (292.1) x 17 (431.8)
MODEL
DIMENSIONS INCHES (mm)
RECOMMENDED CUT-OUT
INSTALLATION
Clean the unit before using. Wipe body and the inside of the unit with a hot, wet cloth to remove any shipping
dust or protective oil.
CAUTION: This device should never be positioned upside down or on its side. If the unit arrived or
was stored in any position other than THIS END UP as marked on the shipping container, then
allow the unit to set upright 24 hours before applying power or turning on the unit. Failure to do this
will cause the unit to function incorrectly. The unit will not be able to cool to the desired temperature.
!
!
ELECTRICAL CONNECTIONS
!
WARNING: Check the data plate on this unit to determine what voltage this unit is wired for and
what voltage service to use.
!
!
CAUTION:When installed, the plug for this unit should be accessible.
!
!
WARNING: Check the data plate on this unit before installation. Connect the unit only to the voltage
and frequency listed on the data plate. Connect only to 1 or 3 phase as listed on the data plate.
!
!
CAUTION:If the power cord is damaged, replace only with an identical power cord.
!
WARNING: IMPROPER GROUNDING COULD RESULT IN ELECTRICAL SHOCK! This
appliance is equipped with a three prong (grounded) plug for your protection against electrical
shock hazard and should be plugged directly into a properly grounded three prong receptacle.
Do not cut or remove the grounding prong from this plug.
!
!
120 Volt
Plug
230 Volt,
50Hz,
CE Plug
To install lower the cold well into a cut out
approximately 11-1/2 by 17 as indicated in the
specification portion of this manual. Make sure there
is enough space for the flanges of the cold well before
cutting the opening. Seal the flange of the cold well to
the countertop using RTV. Allow this to set up before
using your cold well.
NOTE:
To supply air to the compressor system make
sure the counter has openings totaling the area of the
openings to the condenser.