14
Quality for Professionals
6.4 Scheme (HG)
CAUTION
: When changing the motor, it must be ensured that
connection
A
from the control block is connected to connection
B
of the motor and
connection
A
from the motor to connection
B
on the block.
Fig.: 14
A = max.
Hose length 1 m
B = max.
Hose length 1 m
P = marked in
red
BG3
coupling
connector
T = marked in yellow
BG4
coupling connector
(or coupling sleeve)
Engine
B
Engine
A
max = 80 l/min
pmax = 220 bar
A,B = G ½" (bolted connection XGE 15 LR-ED)
P = G ½" (bolted connection XGE 18 LR-ED)
T = G ¾" (bolted connection XGE 22 LR-ED)