Telephone Helpline: 1300 225960
Troubleshooting
If your APURO Pie Warmer develops a fault, please check the following table before making a
service call.
Fault
Probable Cause
Action
The unit is not heating
up and the green
indicator light is Off
The unit is not switched on Check the unit is plugged in correctly
and switched on
switched on
Plug and lead are damaged Call APURO agent or qualified
technician
Fuse in the plug has blown Replace the plug fuse
Power supply
Check power supply
Internal wiring fault
Call APURO agent or qualified
technician
The unit heats up but
the red indicator light is
Off
Indicator light is faulty
Call APURO agent or qualified
technician
The unit is not heating
up or heats up slowly
and the indicator light is
On
Incorrect operation
Ensure:
• thermostat has been set correctly
• doors are closed
• thermostat sensor bulb has not
been removed or damaged
Thermostat failure
Call APURO agent or qualified
technician
Element failure
Call APURO agent or qualified
technician
Technical Specifications
Model
Voltage
Power
Current
Dimensions
h x w x d
(mm)
Weight
(kg)
Approx.
Pie
Capacity
Heat up
Time
(to 90°C)
Operating
Temperatu
re Range
GF454-A
220-240V
50Hz
350W
1.5A
500 x 595 x390
16
30
27 minutes
30 - 90
°
C
GF455-A
220-240V
50Hz
650W
2.8A
582 x 755 x390
23
60
28 minutes
30 - 90
°
C