Страница 3: ...OGY CO LTD No 205 Guangyuan Road Jiangbei District Ningbo 315033 CHINA Phone 86 574 87116972 Fax 86 574 87118655 77000001691 Rev 00 July 22 Importer Distributor Alliage S A Ind strias M dico Odontol g...

Страница 4: ...in this manual may be trademarks registered trademarks or service marks of their respective holders Alliage S A does not make any claim to these brands The use of a term in this manual should not be c...

Страница 5: ...RICAL CONNECTION 17 4 3 PRODUCT PREPARATION 17 4 4 SURGICAL GRADE PAPER REEL INSTALLATION 18 05 OPERATION 20 5 1 PREPARATION 20 5 2 PAPER LOADING 20 5 3 SEALING AND CUTTING 20 5 4 FINISHING 21 06 CLEA...

Страница 6: ...6 Alliage S A Ind strias M dico Odontol gica Phone 55 16 3512 1212 Highway Abr o Assed Km 53 CEP 14097 500 Ribeir o Preto SP Brasil 1 GENERAL INFORMATION...

Страница 7: ...as well as in the solution of small problems that may eventually occur You should read this manual completely and keep it for future reference 1 2 INDICATIONS FOR USE This equipment must be used and...

Страница 8: ...dle with care Maximum Stack Protect from the rain This side Up Manufacturer Manufacturing date General warning Attention Model number Serial number Model Catalog number Indicates that the product must...

Страница 9: ...9 Alliage S A Ind strias M dico Odontol gica Phone 55 16 3512 1212 Highway Abr o Assed Km 53 CEP 14097 500 Ribeir o Preto SP Brasil 2 WARNINGS CAUTIONS AND RECOMMENDATIONS...

Страница 10: ...mpartments General prohibition indication The functionality of the system can be destroyed in the case of incorrect use If unauthorized alterations have been made to the system and the supplied access...

Страница 11: ...sence of vapors from flammable anesthetic mixtures or nitrous oxide Recommendations must be followed During equipment use To operate the equipment the operating personnel must Read and understand the...

Страница 12: ...for which it was conceived For any damages caused to the equipment or operator as a result of incorrect installation and Maintenance procedures in disagreement with the Operating Instructions that ac...

Страница 13: ...13 Alliage S A Ind strias M dico Odontol gica Phone 55 16 3512 1212 Highway Abr o Assed Km 53 CEP 14097 500 Ribeir o Preto SP Brasil 3 GENERAL SYSTEM DESCRIPTION...

Страница 14: ...o the goal of offering a product suitable for the daily needs of the medical dental area 3 2 OPERATION PRINCIPLES Equipment for sealing surgical grade paper by means of bars at high temperature that a...

Страница 15: ...d with the product 01 Surgical grade paper roll 02 Cutting handle 03 Warning LED 04 Operation panel 05 ON Off Key 06 Power cable outlet 07 Sealing handle 08 Support handle 09 Surgical grade paper supp...

Страница 16: ...16 4 INSTALLATION Alliage S A Ind strias M dico Odontol gica Phone 55 16 3512 1212 Highway Abr o Assed Km 53 CEP 14097 500 Ribeir o Preto SP Brasil...

Страница 17: ...ct with water or liquids that could cause short circuits or potentially dangerous situations for the operator Do not install in humid or poorly ventilated environments Do not install in an environment...

Страница 18: ...ALLATION Insert the coil into the surgical grade paper holder Install the surgical grade paper support on the support handles as described in the previous paragraph positioned so that the paper mat un...

Страница 19: ...19 Alliage S A Ind strias M dico Odontol gica Phone 55 16 3512 1212 Highway Abr o Assed Km 53 CEP 14097 500 Ribeir o Preto SP Brasil 5 OPERATION...

Страница 20: ...ADING Pass the surgical grade paper behind and between the pressure and sealing bars so that the paper side is down and the plastic side is up if necessary you can measure the size before sealing and...

Страница 21: ...instruments on the open side of the paper and insert the unsealed end into the front slot a few centimeters until the edge of the paper is aligned with the upper slot G Carry out the sealing operation...

Страница 22: ...22 Alliage S A Ind strias M dico Odontol gica Phone 55 16 3512 1212 Highway Abr o Assed Km 53 CEP 14097 500 Ribeir o Preto SP Brasil 6 CLEANING...

Страница 23: ...ely The application of other solvent based cleaning chemicals or sodium hypochlorite is not recommended as they may damage the equipment Thoroughly dry surfaces and remove any remaining stubborn resid...

Страница 24: ...24 Alliage S A Ind strias M dico Odontol gica Phone 55 16 3512 1212 Highway Abr o Assed Km 53 CEP 14097 500 Ribeir o Preto SP Brasil 7 TROUBLESHOOTING INSPECTION AND MAINTENANCE...

Страница 25: ...sealing handle and lift it back to normal operation The red and green LEDs always light up at the same time 1 The equipment signals the presence of a Problem in the heating system 1 Shut down and try...

Страница 26: ...osition The Fuses of the network are burned Replace Fuses The LED does not flash when the Sealer is on The Led does not work Contact the Authorized Technical Assistance Service Heating resistance is b...

Страница 27: ...re exempt from liability for non compliance with the standard results in cases where the user does not perform the maintenance recommended by the Manufacturer Equipment inspection and maintenance serv...

Страница 28: ...component lists or any other information that provides technical assistance by the user may be requested provided that it is previously agreed between the user and Alliage The Warranty will be void i...

Страница 29: ...29 Alliage S A Ind strias M dico Odontol gica Phone 55 16 3512 1212 Highway Abr o Assed Km 53 CEP 14097 500 Ribeir o Preto SP Brasil 8 TECHNICAL SPECIFICATIONS...

Страница 30: ...m Sealing type At constant temperature Sealing type With continuous cycle and constant temperature Nominal operating temperature of the heating resistance 180 C Maximum sealing length 12 mm Maximum se...

Страница 31: ...against accidental crushing of the fingers during handle movement Automatic Stand By System After a period of 30 minutes of inactivity the machine will go into standby mode turning off the heating el...

Страница 32: ...32 9 WARRANTY Alliage S A Ind strias M dico Odontol gica Phone 55 16 3512 1212 Highway Abr o Assed Km 53 CEP 14097 500 Ribeir o Preto SP Brasil...

Страница 33: ...33 9 WARRANTY This equipment is covered by the warranty periods terms and conditions contained in the Warranty Certificate that accompanies the product...

Страница 34: ...34 Alliage S A Ind strias M dico Odontol gica Phone 55 16 3512 1212 Highway Abr o Assed Km 53 CEP 14097 500 Ribeir o Preto SP Brasil 10 ALLIAGE AUTHORIZED SERVICES...

Страница 35: ...they will not be covered by the warranty Should you need to request electrical diagrams and or component specifications that are not indicated in the user manual contact the Alliage Customer Service t...

Страница 36: ...36...

Страница 37: ...37...

Страница 38: ...38...

Страница 39: ...39...

Страница 40: ...40...