CHAPTER 4
OPERATING INSTRUCTIONS
Entire Contents Copyright
2006
by Adaptive Power Systems, Inc. (APSI) • All Rights Reserved • No reproduction without written authorization from APSI.
FC200 SERIES OPERATIONS MANUAL
4 - 12
FC200-000-02.2
Setting System Parameters
Frequency
Display
Voltage
Display
Current
Display
/
PLC Remote(optional).
Press the CURRENT
︿
or
﹀
buttons to toggle the PLC ON /
OFF in the current display.
OFF
The system is controlled directly from the front panel.
ON
The system is controlled by an external controller that is connected to the 9-PIN
D-sub PLC connector on the rear panel.
Pressing any button on the front panel will cause the display to show PLC-ON, the buzzer to
beep twice, and the display to return to RESET (Standby) mode. The LOCK / LOCAL,
SYSTEM, and P ? PF buttons are the only ones that will function when the PLC feature is ON.
NOTE:
DO NOT use the PLC port for RS-232 serial or GPIB parallel data.
Frequency
Display
Voltage
Display
Current
Display
Alarm Volume.
Press the CURRENT
︿
or
﹀
buttons to adjust the volume of the audible
alarm
0 Minimum volume
9 Maximum volume
Frequency
Display
Voltage
Display
Current
Display
/
/
Power Up.
Press the CURRENT
︿
or
﹀
buttons to step the current display between
OFF/ON/LAST.
▪ OFF
The system will start in standby mode.
▪ ON
The system will power up using default output settings.
▪ LAST
The system will power up using the output settings that were active when it was
last shut down.
Frequency
Display
Voltage
Display
Current
Display
Frequency Hi Limit.
Press the CURRENT
︿
or
﹀
buttons to adjust the frequency limit
value in the current display within the available range: 45.0 – 500.0 Hz. This value sets the
upper frequency limit that can be adjusted during normal operation. The FrEq HI value must
be higher than the FrEq LO value.