22
-
English
5.4
PROGRAMMING THE REMOTE CONTROL
5.4 .1 RADIO START COMMAND (fig.26)
• Remove jumper
JP1
.
• Briefl y press button
P1
.
Ö
Warning light
DL1
is switched
ON for a moment then switched OFF for 1 second and then
ON again:
Ö
programming can begin.
• Press a button on the remote control you wish to program
(this button is used to transmit the
START
command via radio).
Ö
Warning light
DL1
is switched OFF and the command is
programmed.
If a signal is not transmitted within 10 seconds after the
start of programming then programming ends.
Note: a maximum of 48 remote control units can be
programmed to function with the operator.
5.4.2 RADIO COURTESY LIGHT COMMAND (fig.27)
• Insert jumper
JP1
.
• Briefl y press button
P1
twice.
Ö
Warning light
DL1
is
switched ON for a moment then switched OFF for 1 second
and then ON again:
Ö
programming can begin.
• Press a button on the remote control you wish to program
((this button is used to switch ON the
COURTESY LIGHT
).
Ö
Warning light
DL1
is switched OFF and the command is
programmed.
5.4.3 DELEING REMOTE CONTROL UNITS (fig.28)
Note: this operation deletes all previously programmed
remote control units.
• Remove jumper
JP1
.
• Press button
P1
for approximately 10 seconds until warning
light
DL1
is switched OFF.
6. MANUAL ELECTRIC DRIVE:
MANNED
Buttons
P2
and
P3
on the device are the MANUAL
CONTROLS to open and close the door (
fi g.29
).
Warning
!
The limit switches are not enabled in this mode!
Programming / Manned operation
2
1
3
P1
DL1
JP1
fig.26
Remote control
programming: START
3
P1
DL1
2
1
JP1
fig.27
Twice
Remote control programming:
COURTESY LIGHT
1
P1
DL1
JP1
2
10 sec.
fig.28
Deleting remote control units
P2
P3
Manned
functioning
OPEN