21
-
English
JP1
JP1
5. PROGRAMMING AND SETTINGS
5.1
O P E R A T I N G P R O G R A M M I N G ( f i g . 2 2 )
Two types of functioning logic are available. These are set
on the unit using jumper
JP1
:
• Step-by-step functioning (
JP1
open).
• Automatic functioning (
JP1
closed).
5.1.A STEP-BY-STEP FUNCTIONING
(
JP1
open)
• The sequence of movements caused by repeated
START
commands is as follows:
Ö
open
Ö
STOP
Ö
close
Ö
STOP
Ö
open
Ö
...
• Movement is stopped when the limit switch is triggered.
5.1.B AUTOMATIC FUNCTIONING
(
JP1
closed)
• Pressing the
START
command causes the door to open up
to the limit switch.
Ö
The door closes automatically when
the programmed
PAUSE TIME
expires.
5.2
PROGRAMMING THE PAUSE TIME
The PAUSE TIME is the period between conclusion of
opening and the start of closing. This time must be
programmed for automatic functioning.
5.2.1 PAUSE TIME (fig.23)
• Check that the jumper
JP1
is inserted.
• Press button
P1
. Warning light
DL1
is switched ON.
• Wait for the required PAUSE TIME and then press
P1
again. Warning light
DL1
is switched OFF and programming
is complete.
5.2.2 CONDOMINIUM MODE PAUSE TIME (fig.24)
This function inhibits reception of remote control commands
during opening to prevent more than 1 command being
transmitted by users at any given time. Commands are
however accepted during closing.
• Insert jumper
JP1
.
• Press button
P1
.
Ö
Warning light
DL1
is switched ON.
• Remove jumper
JP1
.
• Wait for the required PAUSE TIME and then press
P1
.
Ö
Warning light
DL1
is switched OFF. The procedure is
complete.
• Insert jumper
JP1
to enable automatic functioning in
CONDOMINIUM MODE.
5.3
OBSTACLE DETECTION SETTING
Thanks to the AMPEROSTOP device the operator detects
the presence of obstacles during opening and closing and
then responds automatically.
- During OPENING detection of an obstacle causes the
immediate stop of movement.
- During CLOSING detection of an obstacle causes the
immediate stop of movement and then complete opening.
note: if automatic functioning is set then the door closes
when the pause time has elapsed.
• Use the trimmer
TR1
to adjust the intervention level of the
AMPEROSTOP device (
fi g.25
).
Note: during opening the intervention level is 25%
greater than during closing.
Programming and settings
TR1
m
in
m
a
x
TR1
-
+
fig.25
Adjusting obstacle detection trimmer
1
P1
DL1
JP1
... sec.
2
4
3
fig.23
Programming pause time during opening
P1
DL1
JP1
... sec.
2
5
JP1
1
4
6
3
fig.24
Programming pause time in
condominium mode
fig.22
Operating mode
STEP-BY-STEP:
START
Ö
Open
START
Ö
Stop
START
Ö
Close
START
Ö
Stop
AUTOMATIC:
START
Ö
Open
Ö
Pause
Ö
Close