Installing the Humidifier Control for
Manual Operation

If it is not feasible to install the Outdoor
Temperature Sensor, the Humidifier Control can be
operated in Manual Mode.

1. Connect the Manual Mode Resistor Case wires

to the terminals labeled “ODT” on the Humidifier
Control.

2. Position the Manual Mode Resistor Case so that

the Resistor Case extends from the bottom edge
of the base.

3. Apply the Manual Mode label to the cover,

aligning the sticker and knob holes.

H

W/G Cf

ODT

B

A

C

R

Figure J

90-1220

STEP 9: Route the Wire from Control to Sensor

Run wire to the outdoor temperature sensor. Sensor is not
affected by lead length. Do not run outdoor temperature sensor
alongside wires carrying high voltage (120 VAC or higher).
Secure the sensor bracket with a #8 screw.

STEP 10: Attach Sensor Wire to Humidifier Control

Strip wire 1/4 inch, and insert the wires from the Sensor into the
terminals labeled “ODT” on the Humidifier Control. See

Figure H

for location of terminals.

Figure H

H

W/G Cf

ODT

B

A

C

R

Mode Switch

90-1219

Содержание Automatic Humidifier Control

Страница 1: ...ns WARNING ATTENTION INSTALLER This product must be installed by a qualified heating and air conditioning contractor Failure to do so could result in serious injury from electrical shock READ COMPLETE...

Страница 2: ...en installing the Humidifier Control on a counterflow furnace ensure the blower continues to run after a heat call is satisfied to eliminate high temperatures from damaging the Humidifier Control 5 Do...

Страница 3: ...when the indicator light turns on reminding you to change your water panel If your Control came with a humidifier the Control is pre set for the humidifier If the installation site has a 3 month or s...

Страница 4: ...midifier Control sensor gasket is seated tightly around the drilled hole Do Not Install Control Without Gasket Reattach cover and knob DUCT FIBER BOARD MOUNT After location for Control is selected cut...

Страница 5: ...UCT SHEET METAL PLATE GASKET SCREW x2 INSIDE OF RETURN DUCT Figure E Digital Humidifier Control 24V Terminals 90 1397 H W G Cf ODT B A C R OUTDOOR TEMPERATURE SENSOR OR MANUAL MODE RESISTOR CONTINUOUS...

Страница 6: ...utdoor Temperature Sensor The location of the Outdoor Temperature Sensor must meet these three requirements 1 Must be mounted on North East or West side of house out of direct sunlight 2 Must be at le...

Страница 7: ...de label to the cover aligning the sticker and knob holes H W G Cf ODT B A C R Figure J 90 1220 STEP 9 Route the Wire from Control to Sensor Run wire to the outdoor temperature sensor Sensor is not af...

Страница 8: ...into a constant power source other than the heating ventilating air conditioning equipment HVAC blower circuit The transformer can be powered off the 120 VAC line at the junction box before it enters...

Страница 9: ...ES BROWN WIRES 400 SERIES YELLOW WIRE WHITE WIRE NOTE PLUMB HUMIDIFIER TO HOT WATER WHEN USING THIS WIRING CONFIGURATION 90 1398 USING HUMIDIFIER CONTROL TO ACTIVATE HVAC BLOWER ON CALL FOR HUMIDITY F...

Страница 10: ...ed NOTE The Water Panel Change Indicator must be set to the OFF position for this option Figure P 90 1222 24 VAC TRANSFORMER OUTDOOR TEMPERATURE SENSOR OR MANUAL MODE RESISTOR HEAT PUMP TERMINAL STRIP...

Страница 11: ...ctivate with the Humidifier Control in the Test Reset position refer to the troubleshooting guide 7 Setting the Humidifier Control If the home is occupied set the Humidifier Control to Normal For Manu...

Страница 12: ...ted to the ODT terminals on the Humidifier Control 2 Measure the resistance of the Outdoor Temperature Sensor by removing the leads from the Humidifier Control terminals and measuring the resistance a...

Страница 13: ...ons Check Blower Activation Relay Model 4851 if used for correct installation see Model 4851 instructions Make sure that the saddle valve is open In Test Reset mode the humidifier will operate for 1 m...

Страница 14: ...matic Mode Only Make sure that the Outdoor Temperature Sensor is located at least 3 feet away from all exhaust vents Automatic Mode Only If Outdoor Temperature Sensor is mounted in the fresh air intak...

Страница 15: ...UBLESHOOTING PROCEDURE Check for steady 22 VAC to 30 VAC across the R and C terminals of the Humidifier Control with a voltmeter Check with a voltmeter that the HVAC signal across the W G and Cf termi...

Отзывы: