13
12
Installing the Humidifier Control for
Manual Operation
If it is not feasible to install the Outdoor
Temperature Sensor, the Humidifier Control can be
operated in Manual Mode.
1. Connect the Manual Mode Resistor Case wires
to the terminals labeled “ODT” on the Humidifier
Control.
2. Position the Manual Mode Resistor Case so that
the Resistor Case extends from the bottom edge
of the base.
3. Apply the Manual Mode label to the cover,
aligning the sticker and knob holes.
H
W/G Cf
ODT
B
A
C
R
Figure J
90-1220
STEP 9: Route the Wire from Control to Sensor
Run wire to the outdoor temperature sensor. Sensor is not
affected by lead length. Do not run outdoor temperature sensor
alongside wires carrying high voltage (120 VAC or higher).
Secure the sensor bracket with a #8 screw.
STEP 10: Attach Sensor Wire to Humidifier Control
Strip wire 1/4 inch, and insert the wires from the Sensor into the
terminals labeled “ODT” on the Humidifier Control. See
Figure H
for location of terminals.
Figure H
H
W/G Cf
ODT
B
A
C
R
Mode Switch
90-1219