5

4

STEP 2: Disassemble the Humidifier Control

Remove the knob. Remove the cover by pulling at the bottom and
swinging it out and upward.

STEP 3: Check the Mode Switch

See

Figure H

(on page 12) for the mode switch (labeled A and B).

Make sure the switch is correctly set for the type of humidifier
installed.

Set the Mode Switch in position A for Models:
220, 224, 400 Series, 440, 500 Series, 550, 558,
560, 568, 600 Series, and 700 Series (gray colored
humidifiers only).

Set the Mode Switch in position B for Models:
110, 112, 445, 448, 700 (almond colored humidifier
only), 760, and 768.

Do not operate the humidifier with the Mode Switch in the
wrong position. Damage to the Humidifier Control could result.

STEP 4: Check the Change Water Panel indicator setting.

This setting will control when the indicator light turns on,
reminding you to change your water panel. If your Control came
with a humidifier, the Control is pre-set for the humidifier. If the
installation site has a 3-month or shorter heating season or very
hard water, you may want to adjust the setting (see

Figure B

).

Use the “OFF” setting

to turn the

Water Panel Change Indicator OFF.

NOTE:

When using the Model 50 Current

Sensing Relay, the Water Panel Change
Indicator MUST be OFF.

Use Setting “A”

for Model 400 Series
humidifiers in areas
with very hard water.
The indicator will light
after 150 hours of
humidifier operation.

Use Setting “B”

for Model 400 Series,
500 Series, 600 Series
and 700 Series
humidifiers in areas
with very hard water.
The indicator will light
after 300 hours of
humidifier operation.

Use Setting “C”

for Model 500 Series, 600 Series

and 700 Series humidifiers. The indicator will light
after 600 hours of humidifier operation.

Figure B

Water Panel

Indicator

Settings

90-1202

Содержание Automatic Humidifier Control

Страница 1: ...ns WARNING ATTENTION INSTALLER This product must be installed by a qualified heating and air conditioning contractor Failure to do so could result in serious injury from electrical shock READ COMPLETE...

Страница 2: ...en installing the Humidifier Control on a counterflow furnace ensure the blower continues to run after a heat call is satisfied to eliminate high temperatures from damaging the Humidifier Control 5 Do...

Страница 3: ...when the indicator light turns on reminding you to change your water panel If your Control came with a humidifier the Control is pre set for the humidifier If the installation site has a 3 month or s...

Страница 4: ...midifier Control sensor gasket is seated tightly around the drilled hole Do Not Install Control Without Gasket Reattach cover and knob DUCT FIBER BOARD MOUNT After location for Control is selected cut...

Страница 5: ...UCT SHEET METAL PLATE GASKET SCREW x2 INSIDE OF RETURN DUCT Figure E Digital Humidifier Control 24V Terminals 90 1397 H W G Cf ODT B A C R OUTDOOR TEMPERATURE SENSOR OR MANUAL MODE RESISTOR CONTINUOUS...

Страница 6: ...utdoor Temperature Sensor The location of the Outdoor Temperature Sensor must meet these three requirements 1 Must be mounted on North East or West side of house out of direct sunlight 2 Must be at le...

Страница 7: ...de label to the cover aligning the sticker and knob holes H W G Cf ODT B A C R Figure J 90 1220 STEP 9 Route the Wire from Control to Sensor Run wire to the outdoor temperature sensor Sensor is not af...

Страница 8: ...into a constant power source other than the heating ventilating air conditioning equipment HVAC blower circuit The transformer can be powered off the 120 VAC line at the junction box before it enters...

Страница 9: ...ES BROWN WIRES 400 SERIES YELLOW WIRE WHITE WIRE NOTE PLUMB HUMIDIFIER TO HOT WATER WHEN USING THIS WIRING CONFIGURATION 90 1398 USING HUMIDIFIER CONTROL TO ACTIVATE HVAC BLOWER ON CALL FOR HUMIDITY F...

Страница 10: ...ed NOTE The Water Panel Change Indicator must be set to the OFF position for this option Figure P 90 1222 24 VAC TRANSFORMER OUTDOOR TEMPERATURE SENSOR OR MANUAL MODE RESISTOR HEAT PUMP TERMINAL STRIP...

Страница 11: ...ctivate with the Humidifier Control in the Test Reset position refer to the troubleshooting guide 7 Setting the Humidifier Control If the home is occupied set the Humidifier Control to Normal For Manu...

Страница 12: ...ted to the ODT terminals on the Humidifier Control 2 Measure the resistance of the Outdoor Temperature Sensor by removing the leads from the Humidifier Control terminals and measuring the resistance a...

Страница 13: ...ons Check Blower Activation Relay Model 4851 if used for correct installation see Model 4851 instructions Make sure that the saddle valve is open In Test Reset mode the humidifier will operate for 1 m...

Страница 14: ...matic Mode Only Make sure that the Outdoor Temperature Sensor is located at least 3 feet away from all exhaust vents Automatic Mode Only If Outdoor Temperature Sensor is mounted in the fresh air intak...

Страница 15: ...UBLESHOOTING PROCEDURE Check for steady 22 VAC to 30 VAC across the R and C terminals of the Humidifier Control with a voltmeter Check with a voltmeter that the HVAC signal across the W G and Cf termi...

Отзывы: