2

MOUNTING AND WIRING

ELECTRIC HEAT OR SINGLE-STAGE HEAT PUMP SYSTEMS

This thermostat is confi gured from the factory to operate a heat/cool, 
fossil fuel (gas, oil, etc.), forced air system. It is confi gured correctly 
for any system that DOES NOT require the thermostat to energize 
the fan on a call for heat. If your system is an electric or heat-pump 
system that REQUIRES the thermostat to turn on the fan on a call for 
heat, locate the 

ELECTRIC/GAS 

switch (see 

Figure 1

) and switch it 

to the 

ELECTRIC

 position. This will allow the thermostat to energize 

the fan immediately on a call for heat. If you are unsure if the 
heating/cooling system requires the thermostat to control the fan, 
contact a qualifi ed heating and air conditioning service person.

HYDRONIC (HOT WATER OR STEAM) HEATING SYSTEMS

This thermostat is set to operate properly with a forced-air heating 
system. If you have a hydronic heating system (a system that heats 
with hot water or steam), you must set the thermostat to operate 
properly with your system by changing the fi rst option in the 
confi guration menu to SL (see Confi guration Menu, page 5).

Take care when securing and routing wires so they do 
not short to adjacent terminals or rear of thermostat. 
Personal injury and/or property damage may occur.

 CAUTION

THERMOSTAT APPLICATIONS

Description

Standard Heat Only Gas or Oil Fired Systems (24 volt)*

Yes

Electronic Ignition Heat Only Two Wire Systems (24 volt)*

Yes

Electronic Ignition Heat Only Gas or Oil Fired Systems (24 volt)*

Yes

Standard Heat/Cool Systems (24 volt)*

Yes

Heat/Cool Systems Electric Heat (24 volt)*

Yes

Heat Only Electric Heat Systems (24 volt)*

Yes

Cool Only Systems (24 volt)*

Yes

Heat Pump Systems (No Aux or Emergency Heat)*

Yes

Description

Hot Water Zone Heat Only Systems

No

Hot Water Zone Heat Only (Three Wire) Systems

No

Line Voltage Heating or Baseboard 110/240 Volt Systems

No

Millivolt Systems Floor or Wall Furnaces

No

12 VDC Mobile Home Application

No

Multi-stage Systems

No

Systems Exceeding 30VAC, 1.5 Amp

No

*Requires common wire for 24VAC at the thermostat

Terminal Cross Reference Chart

New Thermostat 

Terminal Designation

Other Manufacturers’ 
Terminal Designation

RH

4

RH

M

*

R

RC

R

R

V

G

G

G

F

G

W

W

W

H

W

Y

Y

Y

C

Y

C

C

C

X

C

*Factory installed jumper wire between the 

RH

 and 

RC

 terminals must remain in place.

120 volts may cause serious injury from electrical 
shock. Disconnect electrical power to the furnace & air 
conditioner before starting installation. This thermostat 
is not a 120 volt (line voltage) device.

Improper installation may cause serious injury from electrical 
shock. This product must be installed by a qualifi ed 
heating & air conditioning contractor in accordance with 
NEC Standards and applicable local and state codes.

Do not use on circuits exceeding specifi ed voltage. 
Higher voltage will damage control and could cause 
shock or fi re hazard.

Do not short out terminals on gas valve or primary control 
to test. Short or incorrect wiring will damage thermostat 
and could cause personal injury and/or property damage.

Thermostat installation and all components of the system 
shall conform to Class II circuits per NEC code.

 WARNING

CHOOSE A LOCATION TO MOUNT THE THERMOSTAT

MOUNT THE THERMOSTAT…

•  Approximately 5 feet above the fl oor. Refer to local codes for 

compliance with the Americans with Disabilities Act (ADA).

•  On an interior wall in a frequently occupied space where the 

temperature is most representative of the zone being controlled 
by the thermostat.

•  At least 18 inches away from an outside wall.

DO NOT MOUNT THE THERMOSTAT…

•  Behind doors, in corners or other dead air spaces.

•  In direct sunlight, near lamps or other sources of heat.

•  On an outside wall or any wall exposed to an unconditioned space 

(a garage for example).

•  In the airfl ow path of a supply register, in stairways or near 

outside doors.

•  On a wall where concealed pipes or ductwork will affect the 

thermostat temperature accuracy.

•  Near sources of electrical interference, such as arcing switch contacts.

Содержание 8263

Страница 1: ... drill bit if needed Flat blade screwdriver Wire cutter stripper Level THERMOSTAT DETAILS Mounting hole Mounting hole Electric Gas Switch FIGURE 1 Thermostat Base Failure to follow and read all instructions carefully before installing or operating this control could cause personal injury and or property damage If you have any questions please call Research Products Corporation at 800 334 6011 ...

Страница 2: ...Wall Furnaces No 12 VDC Mobile Home Application No Multi stage Systems No Systems Exceeding 30VAC 1 5 Amp No Requires common wire for 24VAC at the thermostat Terminal Cross Reference Chart New Thermostat Terminal Designation Other Manufacturers Terminal Designation RH 4 RH M R RC R R V G G G F G W W W H W Y Y Y C Y C C C X C Factory installed jumper wire between the RH and RC terminals must remain...

Страница 3: ...UIPMENT IS OFF a Make sure the fan switch is set to Auto and the Mode switch is set to Off b Strip 3 of cable insulation c Strip 3 8 of insulation from each wire Do not cut into the wire when stripping insulation as this can lead to eventual control failure d Secure the wires to the thermostat terminal strip according to the wiring diagram for the model being installed see Figures 2 through 7 Use ...

Страница 4: ...ng above room temperature The heating system should begin to operate 3 Press to adjust temperature setting below room temperature The heating system should stop operating OPERATING FEATURES Now that you are familiar with the thermostat buttons and display read the following information to learn about the many features of the thermostat SIMULTANEOUS HEATING COOLING PROGRAM STORAGE When programming ...

Страница 5: ...e the thermostat setpoint will change to 70 at 6 35 AM Cooling allows more time per degree because it takes longer to reach temperature 4 Select Compressor Lockout LOC OFF or ON Selecting LOC ON will cause the thermostat to wait 5 minutes before turning on the compressor if the heating and cooling system loses power It will also wait 5 minutes minimum between cooling cycles This is intended to hel...

Страница 6: ...heating program periods Weekday heating programs are now complete 8 Press PRGM once SA SU indicating weekend program will appear in the display along with the start time for the 1st heating period and the currently programmed temperature 9 Repeat steps 4 through 8 to complete weekend heating programming 10 When you have completed entering your heating program press RUN ENTER COOLING PROGRAM If the...

Страница 7: ...furnace manufacturer or local service person for assistance 5 Diagnostic Set System Switch to HEAT and raise the setpoint above room temperature Within a few seconds the thermostat should make a soft click sound This sound usually indicates the thermostat is operating properly If the thermostat does not click try the reset operation listed above If the thermostat does not click after being reset c...

Страница 8: ...l fan system 4 Fan Switch set to Fan On 1 4 Check each wire connection to verify they are not shorted or touching together No bare wire should stick out from under terminal screws Try resetting the thermostat as described on page 7 If the condition persists the manufacturer of your system or service person can instruct you on how to test the Heat Cool system for correct operation If the system ope...

Отзывы: