background image

6

PROGRAMMING YOUR THERMOSTAT 

(CONTINUED)

ENTERING YOUR PROGRAM

Follow these steps to enter the heating and cooling programs you 
have selected.

Set Current Time and Day

1.  Press TIME button once. The display will show the hour only.

EXAMPLE:

  

2.  Press and hold either 

 or 

 until you reach the correct 

hour and AM/PM designation (

AM

 begins at midnight; 

PM

 begins 

at noon).

3.  Press TIME once. The display window will show the minutes only.

EXAMPLE:

  

4.  Press and hold either 

 or 

 until you reach the correct 

minutes.

5.  Press TIME once. The display will show the day of the week.

6.  Press 

 or 

 until you reach the current day of the week.

7.  Press RUN once. The display will show the correct time and room 

temperature alternately.

ENTER HEATING PROGRAM

1.  Move the SYSTEM switch to 

HEAT

.

2.  Press PRGM once. “

MO TU WE TH FR

” (indicating weekday 

program) will appear in the display. Also displayed are the currently 
programmed start time for the 

1st heating

 period and the currently 

programmed temperature (fl ashing).

EXAMPLE:

  

   This display window shows that for the 1st weekday period, the 

start time is 6:00 AM, and 70° is the programmed temperature 
(this example refl ects factory preprogramming).

3.  Press 

 or 

 to change the displayed temperature to your 

selected temperature for the 1st heating program period. 

4.  Press TIME once (the programmed time will fl ash). Press 

 

or 

 until your selected time appears. The time will change in 

15 minute increments. When your selected time is displayed, press 
TIME again to return to the change temperature mode.

5.  Press PRGM once. The currently programmed start time and setpoint 

temperature for the 

2nd heating

 program period will appear.

6.  Repeat steps 4 and 5 to select the start time and heating 

temperature for the 2nd heating program period.

7.  Repeat steps 4 through 6 for the 3rd and 4th heating program 

periods. Weekday heating programs are now complete.

8.  Press PRGM once. “

SA SU

” (indicating weekend program) will 

appear in the display, along with the start time for the 1st heating 
period and the currently programmed temperature.

9.  Repeat steps 4 through 8 to complete weekend heating 

programming.

10.  When you have completed entering your heating program, 

press RUN.

ENTER COOLING PROGRAM

If the outside temperature is below 50°F, disconnect power 
to the cooling system before programming. Energizing the 
air conditioner compressor during cold weather may cause 
personal injury or property damage.

1.  Move SYSTEM switch to 

COOL

 position.

2.  Follow the procedure for entering your heating program, using 

your selected cooling times and temperatures.

CHECK YOUR PROGRAMMING

Follow these steps to check your thermostat programming one fi nal 
time before beginning thermostat operation.

1.  Move SYSTEM switch to 

HEAT

 position.

2.  Press PRGM to view the 1st weekday heating period time and 

temperature. Each time you press PRGM, the next heating period 
time and temperature will be displayed in sequence for weekday, 
then weekend program periods (you may change any time or 
temperature during this procedure).

3.  Press RUN.

4.  Move SYSTEM switch to 

COOL

 position.

5.  Repeat step 2 to check cooling temperatures.

6.  Press RUN to begin program operation. 

YOUR THERMOSTAT IS NOW FULLY PROGRAMMED AND 
READY TO AUTOMATICALLY PROVIDE MAXIMUM COMFORT 
AND EFFICIENCY!

Heating/Cooling Schedule Plan (Factory Program)

Period

Weekday (5 Day)

Weekend (2 Day)

Start Time

Temperature

Start Time

Temperature

HEA

T

1ST

6:00 AM

70°F

6:00 AM

70°F

2ND

8:00 AM

62°F

8:00 AM

62°F

3RD

5:00 PM

70°F

5:00 PM

70°F

4TH

10:00 PM

62°F

10:00 PM

62°F

COOL

1ST

6:00 AM

78°F

6:00 AM

78°F

2ND

8:00 AM

85°F

8:00 AM

85°F

3RD

5:00 PM

78°F

5:00 PM

78°F

4TH

10:00 PM

82°F

10:00 PM

82°F

My Heating/Cooling Schedule Plan

Period

Weekday (5 Day)

Weekend (2 Day)

Start Time

Temperature

Start Time

Temperature

HEA

T

1ST

2ND

3RD

4TH

COOL

1ST

2ND

3RD

4TH

Содержание 8263

Страница 1: ... drill bit if needed Flat blade screwdriver Wire cutter stripper Level THERMOSTAT DETAILS Mounting hole Mounting hole Electric Gas Switch FIGURE 1 Thermostat Base Failure to follow and read all instructions carefully before installing or operating this control could cause personal injury and or property damage If you have any questions please call Research Products Corporation at 800 334 6011 ...

Страница 2: ...Wall Furnaces No 12 VDC Mobile Home Application No Multi stage Systems No Systems Exceeding 30VAC 1 5 Amp No Requires common wire for 24VAC at the thermostat Terminal Cross Reference Chart New Thermostat Terminal Designation Other Manufacturers Terminal Designation RH 4 RH M R RC R R V G G G F G W W W H W Y Y Y C Y C C C X C Factory installed jumper wire between the RH and RC terminals must remain...

Страница 3: ...UIPMENT IS OFF a Make sure the fan switch is set to Auto and the Mode switch is set to Off b Strip 3 of cable insulation c Strip 3 8 of insulation from each wire Do not cut into the wire when stripping insulation as this can lead to eventual control failure d Secure the wires to the thermostat terminal strip according to the wiring diagram for the model being installed see Figures 2 through 7 Use ...

Страница 4: ...ng above room temperature The heating system should begin to operate 3 Press to adjust temperature setting below room temperature The heating system should stop operating OPERATING FEATURES Now that you are familiar with the thermostat buttons and display read the following information to learn about the many features of the thermostat SIMULTANEOUS HEATING COOLING PROGRAM STORAGE When programming ...

Страница 5: ...e the thermostat setpoint will change to 70 at 6 35 AM Cooling allows more time per degree because it takes longer to reach temperature 4 Select Compressor Lockout LOC OFF or ON Selecting LOC ON will cause the thermostat to wait 5 minutes before turning on the compressor if the heating and cooling system loses power It will also wait 5 minutes minimum between cooling cycles This is intended to hel...

Страница 6: ...heating program periods Weekday heating programs are now complete 8 Press PRGM once SA SU indicating weekend program will appear in the display along with the start time for the 1st heating period and the currently programmed temperature 9 Repeat steps 4 through 8 to complete weekend heating programming 10 When you have completed entering your heating program press RUN ENTER COOLING PROGRAM If the...

Страница 7: ...furnace manufacturer or local service person for assistance 5 Diagnostic Set System Switch to HEAT and raise the setpoint above room temperature Within a few seconds the thermostat should make a soft click sound This sound usually indicates the thermostat is operating properly If the thermostat does not click try the reset operation listed above If the thermostat does not click after being reset c...

Страница 8: ...l fan system 4 Fan Switch set to Fan On 1 4 Check each wire connection to verify they are not shorted or touching together No bare wire should stick out from under terminal screws Try resetting the thermostat as described on page 7 If the condition persists the manufacturer of your system or service person can instruct you on how to test the Heat Cool system for correct operation If the system ope...