background image

SERVICE PARTS

8

7

3

4

5

9

1

6

2

13

10

18

11

14

17

19

16

12

15

No.

Part Description

Part No.

1

Filter, 10” x 12” x 1” EZK

5443

2

Internal Control Board

5444

3

User Interface Assembly

5564

4

Wiring Access Door

5446

5

Hole Cover, UI Ctrl

5447

6

Door, Filter Access

5448

7

Outlet Duct Panel

5449

8

Backflow Damper, 10”

5450

9

Inlet Duct Panel

5451

10

Cover, Outlet

5452

No.

Part Description

Part No.

11

Model 8191 Fan

5453

Model 8192 Fan

5467

12

Wire Harness, Power

5454

13

Sensor, Low Temperature

5455

14

Sensor, High Temperature

5456

15

Leveling Foot

5457

16

Capacitor, 45MFD, 370VAC

5458

17

Model 8191 Capacitor, 8MFD, 450VAC

5459

Model 8192 Capacitor, 12MFD, 450VAC

5468

18

RH Sensor

5460

19

Drain Tube + Fittings

5461

90-1906

15

Содержание 8191

Страница 1: ...d in the upright position WARNING 1 120 Volts may cause serious injury from electric shock Disconnect electrical power before starting installation or servicing Leave power disconnected until installa...

Страница 2: ...ly designed homes while removing moisture from the air Simply duct the inlet of the ventilator to an outdoor air intake and duct the discharge to the return side of the HVAC system Plug the unit in se...

Страница 3: ...able TABLE 1A Model 8191 Ventilation Performance External Static w c Airflow CFM Power W Current A CFM watt CFM watt FAN ONLY 0 160 63 57 2 54 4 48 0 1 140 63 56 2 22 3 97 0 2 120 63 56 1 90 3 55 0 3...

Страница 4: ...ilator The outlet collar has a backflow damper The outlet duct collar may be attached to the top or end of the unit Move the outlet cover to the location not being used See Figure 2 Make sure there ar...

Страница 5: ...cure the control with the same four screws used to attach the control to the top of the unit 6 Secure the control panel cover to the top of the unit FIGURE 3 Control Location 90 1884 LOCATION CONSIDER...

Страница 6: ...ubing to curl up which may result in air lock NOTE Always use PVC primer and cement when connecting PVC drain line or the provided fitting to the dehumidifier drain outlet Always install the ventilato...

Страница 7: ...Certified Homes requirements Wire the control to the HVAC system as show in Figure 8 Wiring to the HVAC system allows the ventilator to turn on when the HVAC system is running for improved circulatio...

Страница 8: ...utes TABLE 3 Cycle Time Setting minutes for Airflow Delivered vs Airflow Required for 1 Hour Cycle CFM Delivered CFM Required 20 30 40 50 60 70 80 90 100 110 60 20 30 40 50 60 80 15 25 30 40 45 55 60...

Страница 9: ...854 An external control such as a thermostat can be used to turn ventilation on and off with External Control ENABLED The Remote Control option is not available when External Control is enabled Model...

Страница 10: ...or and all of the wired components will turn on and off during Installer Test Mode to demonstrate that all are properly operating Installer Test Mode lasts for four 4 minutes If the ON OFF button is p...

Страница 11: ...tween the DH terminals of the Model 8191 8192 control The external control determines when ventilation occurs Dehumidification of the incoming air is still controlled as described below even if an ext...

Страница 12: ...m water and a mild detergent solution 5 Shake off the excess water from the filter 6 Replace the filter making sure the filter is secured in both the top and bottom filter rails 7 Replace the filter a...

Страница 13: ...re is significantly lower than the air temperature the Frost Sensor will need to be replaced Part No 5455 5 If the sensor is OK turn up the humidity setting to seven 7 to turn on the compressor Allow...

Страница 14: ...ng Lack of or reduced airflow Check ventilator air filter and wash or replace Check for blocked duct work Inlet air conditions below 60 F Increase the humidity setting Inlet air temperature is outside...

Страница 15: ...5448 7 Outlet Duct Panel 5449 8 Backflow Damper 10 5450 9 Inlet Duct Panel 5451 10 Cover Outlet 5452 No Part Description Part No 11 Model 8191 Fan 5453 Model 8192 Fan 5467 12 Wire Harness Power 5454...

Страница 16: ...P O Box 1467 Madison WI 53701 1467 Phone 800 334 6011 Fax 608 257 4357 www aprilairepartners com 10010925 4 17 B2206395E Printed in U S A 2017 Aprilaire A division of Research Products Corporation...

Отзывы: