CONTROL
PANEL COVER
CONTROL
CONTROL
CONTROL
PANEL COVER
FILTER ACCESS DOOR
SET UP VENTILATOR FOR INSTALLATION
(CONTINUED)
CONTROL LOCATION
The on-board control can be located on the top of
the ventilator or can be relocated to the front of the
ventilator .
To move the control:
1 . Remove the front control panel cover .
2 . Remove the filter access door and filter .
3 . Detach the on-board control by removing the four
(4) screws around the control .
NOTE:
Use one
hand to support the bottom of the on-board control
when removing .
4 . Keep the control in the unit and relocate to the
front access hole .
5 . Secure the control with the same four screws
used to attach the control to the top of the unit .
6 . Secure the control panel cover to the top of the
unit .
FIGURE 3 – Control Location
90-1884
LOCATION CONSIDERATIONS
TOP VIEW
FILTER
MINIMUM
CLEARANCE FOR FILTER
(EITHER SIDE)
13"
6" MINIMUM CLEARANCE
FOR PROPER AIR FLOW
ELECTRICAL SERVICE
ACCESS THIS SIDE
6 FT. POWER CORD
FIGURE 4 – Filter Access Clearance
90-1840
• Allow sufficient clearance for filter removal and to
prevent airflow obstruction
• Electrical service access will require the removal
of the side panel shown . Allow sufficient space for
service on this side of the unit .
• For attic installations, it is recommended that the
ventilator be suspended .
• Always install the ventilator in a condensate pan
when locating in or over a finished space .
5