![Aprilaire 1820 Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/aprilaire/1820/1820_installation-instructions-and-owners-manual_2956098006.webp)
SYSTEM SET-UP, CHECK & START-UP
If using a Model 76 Remote Control and/or the Air Cycling feature,
proceed to
Step 1
below . If not using either feature, proceed to
SYSTEM CHECK
on page 7 .
1.
Check all wiring .
2.
Make sure the wire access cover has been snapped back onto the
on-board control .
3.
Plug unit in and turn power switch to ON . The power switch is
located on the dehumidifier outlet next to the power cord .
4.
The on-board control screen should display OFF .
90-1854
NOTE:
If the display backlight is not on, the first button press (any
button) will only turn on the backlight . Press the button a second time
to achieve function .
5.
Hold the MODE button on the on-board control for 3 seconds to
enter the Installer Set-up Menu .
6.
Navigate through the following screens to set up the dehumidifier
for the installed application .
Use the UP or DOWN arrows to select items and use MODE to
switch to the next set-up option . To exit installer set-up, all options
must be scrolled through using the MODE button .
7.
After the installer set up options have been completed, DONE will
blink for 3 seconds and the control will return to the OFF screen .
90-1854
90-1854
REMOTE CONTROL – CRAWL SPACE
90-1854
If not installing in a crawl space
with Model 76 remote control,
press MODE to go to VENT screen
selections
90-1854
If installing in a crawl space with
remote control, Enable and press
MODE . The installer set-up is
complete, proceed to
SYSTEM
CHECK
on page 7 .
NOTE:
Air Cycling is not an
option when Remote is enabled .
6