6 Special Functions:
6.1 Pump exercise function:
If pumps are not activated for a period of 48 hours, this function will automatically
activate them for 15 seconds to avoid jams.
6.2 Dimmer function:
To save power, the backlight automatically dims if there is no keypad activity for a
period of 10 minutes.
6.3 Security function:
To avoid unintentional/unauthorized changes,
System
type and
Extra Function
selection (
No
,
Thermostat
,
Cooling
, or
Diffcontrol
) are inaccessible after the
control has been connected to an electrical source for a period of15 minutes.
If you want to modify these parameters at any time past the 15 minute settings lock,
you must disconnect and reconnect the power to the controller.
•
This action will not reset the control; it will only allow access to make
modifications.
To reset all of the control settings to the factory default values, see
Services
/
section
1.8 Reset to factory default settings
.
7 Ohm to °F Conversion Chart for PT1000 Sensors:
Sensor temperature can be read with an Ohmmeter as a preliminary troubleshooting
measure by the following method:
Perform this test only after disconnecting the sensor.
•
Disconnect the sensor leads from the solar control.
•
Connect the leads to an Ohmmeter.
•
Use the following chart to determine the approximate temperature at the
sensor bulb.
-14°F (-10°C)
960 ohms
140°F ( 60°C)
1232 ohms
32°F (
0°C)
1000 ohms
158°F ( 70°C)
1271 ohms
50°F ( 10°C)
1039 ohms
176°F ( 80°C)
1309 ohms
68°F ( 20°C)
1077 ohms
194°F ( 90°C)
1347 ohms
86°F ( 30°C)
1116 ohms
212°F (100°C)
1385 ohms
104°F( 40°C)
1155 ohms
248°F (120°C)
1461 ohms
122°F( 50°C)
1194 ohms
284°F (140°C)
1535 ohms